Large Soil Campaign Underway at Bauloora Epithermal Project
Released
Released
Announcement PDF
ASX ANNOUNCEMENT
23 JUNE 2022
Large Scale Soil Campaign Commences Across Low-Sulphidation
Targets at Bauloora
Visible Gold/Electrum Observed During First Pass Field Work
Legacy Minerals Holdings Limited (ASX: LGM, “LGM”, “the Company” or “Legacy Minerals”)
is pleased to provide an update on the exploration program at its Bauloora Project.
Phase 1 Anomalous Gold Zone Soil Program
•
•
•
•
The Company will take approximately 2,500 samples across the northern portion of the
10km2 anomalous gold zone.
Samples will undergo multi-element analysis including for gold, silver and base metals.
The Program commenced this week and will take approximately four weeks to complete.
The Company’s handheld pXRF will deliver immediate results for interpretation with the
soils then sent for lab analysis with all results expected within ten weeks.
Encouraging First Pass Rock Chip Sampling
•
•
First past rock sampling is also underway with gold/electrum (Figure 1) identified along
strike at the Mee Mar Prospect extending the strike extent of continuous veins.
Follow up rock chip sampling has also identified several new areas exhibiting epithermal
veining coincident with observed elevated resistivity trends in the GA-IP survey1.
Building on a Successful Maiden Drill Campaign at Mt Felstead
•
The objectives of the program will be to identify further high-grade gold-silver zones and
build on the success of the maiden drill campaign which returned individual assays up to
422g/t Ag, 8.9g/t Au, and 29.3% Pb+Zn2.
Management Comment
Legacy Minerals Managing Director, Christopher Byrne said:
“The Bauloora epithermal zone, an 8km2 footprint contained within a much larger area of
hydrothermal alteration and mineralisation, has had limited systematic exploration from past
explorers. This large soil program is a critical step in building a comprehensive picture of the
widespread extent of the mineralisation.
It is incredible that to date, considering the high-grade drill intercepts, bonanza historical
production, and widespread epithermal veins that there is so limited historical sampling across
the broader project area.
We will be using the results of the program to map the scale and extent of the system and to
constrain drill targets within the project area. The Company is fully funded to drill test resulting
targets and we look forward to keeping our shareholders updated on the results.
1
ASX LGM 16 March 2022: Large Low Sulphidation System Highlighted by GA-IP Survey
2
ASX LGM 16 June 2022: High-Grade Silver, Gold Drill Results, Met-Testing Underway
ABN 43 650 398 897
Level 7, 1 Margaret Street Sydney
ASX: LGM
Page 1 of 10
www.legacyminerals.com.au
Bauloora – One of NSW’s Largest Epithermal Systems
•
•
•
The Project covers 27km2 of hydrothermal alteration and mineralisation as is one of the
largest epithermal systems in NSW.
Less than 5% of this epithermal alteration footprint area has been covered by soil or rock
chip geochemistry from previous exploration companies.
Previous sampling has identified rock chips up to 39.1g/t Au and 267g/t Ag3
Figure 1: Sample No 4234: Observed visible gold or electrum (Au/Ag alloy)4 within saccharoidal
quartz vein cross cutting quartz, carbonate and adularia colloform-crustiform banded epithermal
vein at the Mee Mar Prospect
Soil Program
Soil geochemistry surveys have been a proven exploration method used to identify areas of
interest across epithermal projects globally. The Company plans to take ~2,500 samples
across the northern section of the anomalous gold zone (Figure 2) and conduct multi-element
analysis including for gold, silver and base metals. The Program has commenced this week
and will take approximately four weeks to complete with immediate testing using a handheld
pXRF for initial interpretation with the soils then sent for lab analysis with all results expected
within ten weeks.
3
Company’s Prospectus dated 28 July 2021 lodged 9 September 2021 (ASX: LGM)
4
Note with respect to any visible gold observed, it must be cautioned that visual observations are uncertain in nature and should not be
taken as a substitute for appropriate laboratory analysis. Laboratory assays will be reported when they are received and interpreted.
Page 2 of 10 | ABN 43 650 398 897
Level 7, 1 Margaret Street Sydney
www.legacyminerals.com.au
ASX: LGM
Figure 2: Planned soil program across northern section of the Bauloora anomalous gold zone
showing drill intercepts and prospects.
Page 3 of 10 | ABN 43 650 398 897
Level 7, 1 Margaret Street Sydney
www.legacyminerals.com.au
ASX: LGM
Examples of Epithermal Vein Textures from First Past Rock Sampling
Sample 3933: Colloformcrustiform chalcedony
(quartz)-carbonate-adularia
vein
Sample ID 2940: Cockade
textured breccia with
colloform-crustiform quartzcarbonate-adularia banding
Sample ID 2934: Colloformcrustiform quartz-carbonate
vein within argillic altered
dacite
Page 4 of 10 | ABN 43 650 398 897
Level 7, 1 Margaret Street Sydney
www.legacyminerals.com.au
ASX: LGM
Approved by the Board of Legacy Minerals Holdings Limited.
For more information:
Chris Byrne
CEO & Managing Director
chris.byrne@legacyminerals.com.au
+61 (0) 499 527 547
Victoria Humphries
Media & Investor Relations
victoria@nwrcommunications.com.au
+61 (0) 431 151 676
DISCLAIMER AND PREVIOUSLY REPORTED INFORMATION
Information in this announcement is extracted from reports lodged as market announcements referred to above
and available on the Company’s website https://legacyminerals.com.au/. The Company confirms that it is not
aware of any new information that materially affects the information included in the original market
announcement and that all material assumptions and technical parameters underpinning the estimates in the
relevant market announcement continue to apply and have not materially changed.
This announcement contains certain forward-looking statements. Forward looking statements are only
predictions and are subject to risks, uncertainties and assumptions which are outside of the control of Legacy
Minerals Holdings Limited (LGM). These risks, uncertainties and assumptions include commodity prices,
currency fluctuations, economic and financial market conditions, environmental risks and legislative, fiscal or
regulatory developments, political risks, project delay, approvals and cost estimates. Actual values, results or
events may be materially different to those contained in this announcement. Given these uncertainties, readers
are cautioned not to place reliance on forward-looking statements. Any forward-looking statements in this
announcement reflect the views of LGM only at the date of this announcement. Subject to any continuing
obligations under applicable laws and ASX Listing Rules, LGM does not undertake any obligation to update or
revise any information or any of the forward-looking statements in this announcement to reflect changes in
events, conditions or circumstances on which any forward-looking statements is based.
COMPETENT PERSON’S STATEMENT
The information in this report that relates to Exploration Targets, Exploration Results, Mineral Resources or Ore
Reserves is based on information compiled by Thomas Wall, a Competent Person who is a Member of the
Australian Institute of Geoscientists. Mr Wall is the Technical Director and a full-time employee of Legacy
Minerals Pty Limited, the Company’s wholly owned subsidiary, and a shareholder of the Company. Mr Wall has
sufficient experience that is relevant to the style of mineralisation and type of deposit under consideration and
to the activity being undertaken to qualify as a Competent Person as defined in the 2012 edition of the
Australasian Code for Reporting of Exploration Results, Mineral Resources and Ore Reserves. Mr Wall consents
to the inclusion in the report of the matters based on his information in the form and context in which it appears
in this announcement.
REFERENCED DOCUMENTS
Company’s Prospectus dated 28 July 2021 lodged 9 September 2021 (ASX: LGM)
ASX LGM 11 April 2022: Outstanding High-Grade Drilling Assays Returned at Bauloora
ASX LGM 16 March 2022: Large Low Sulphidation System Highlighted by GA-IP Survey
ASX LGM 16 June 2022: High-Grade Silver, Gold Drill Results, Met-Testing Underway
Page 5 of 10 | ABN 43 650 398 897
Level 7, 1 Margaret Street Sydney
www.legacyminerals.com.au
ASX: LGM
About Legacy Minerals
Legacy Minerals is an ASX listed public company that has been involved in the acquisition and
exploration of gold, copper, and base-metal projects in the Lachlan Fold Belt since 2017. The
Company has six wholly owned and unencumbered tenements that present significant discovery
opportunities for shareholders.
Au-Cu (Pb-Zn) Cobar (EL8709, EL9256)
Au Harden (EL8809, EL9257)
Undrilled targets next door to the Peak Gold Mines with
several priority geophysical anomalies Late time AEM
conductors, IP anomaly, and magnetic targets
Geochemically anomalous - gold in lag up to 1.55g/t Au.
Large historical high-grade quartz-vein gold
mineralisation open along strike and down plunge.
Significant drill intercepts include 3.6m at 21.7g/t Au
116m and 2m at 17.17g/t Au from 111m.
Au-Ag Bauloora (EL8994)
Au-Cu Fontenoy (EL8995)
2
A 27km hydrothermal alteration area containing lowsulphidation epithermal-style gold silver targets.
Historical bonanza grades at the Mt Felstead Prospect
included face sampling up to 3,701g/t Ag, 6.9g/t Au,
29% Pb, 26% Zn, and 6.4% Cu.
The Project exhibits a greater than 8km long zone of Au
and Cu anomalism defined in soil sampling and drilling.
Significant drill intercepts include 79m at 0.27% Cu from
1.5m with numerous untested anomalies along the 8km
strike length.
Cu-Au Rockley (EL8296)
Sn-Ni-Cu Mulholland (EL9330)
Prospective for porphyry Cu-Au and situated in the
Macquarie Arc Ordovician host rocks the project
contains historic high-grade copper mines that graded
up to 23% Cu.
Associated polymetallic mineralisation. There are
several tin and nickel occurrences in the project area
with trends up to 2.6km defined in drilling. Significant
drill intercepts include 44m at 0.45% Ni.
Figure 3: Legacy Minerals Tenements, NSW, Australia
ABN 43 650 398 897
Level 7, 1 Margaret Street Sydney
ASX: LGM
Page 6 of 10
www.legacyminerals.com.au
Appendix 2 – JORC Code, 2021 Edition Table 1
Section 1 Sampling Techniques and Data
Criteria
JORC Code Explanation
Commentary
Nature and quality of sampling (e.g., cut channels,
random chips, or specific specialised industry
standard measurement tools appropriate to the
minerals under investigation, such as down hole
gamma sondes, or handheld XRF instruments,
etc). These examples should not be taken as
limiting the broad meaning of sampling.
Include reference to measures taken to ensure
sample representivity and the appropriate
calibration of any measurement tools or
systems used.
Rock chip and grab samples were taken from numerous
locations throughout the prospect areas.
Aspects of the determination of mineralisation
that are Material to the Public Report.
In cases where ‘industry standard’ work has
been done this would be relatively simple (e.g.
‘reverse circulation drilling was used to obtain 1
m samples from which 3 kg was pulverised to
produce a 30 g charge for fire assay’). In other
cases more explanation may be required, such
as where there is coarse gold that has inherent
sampling problems. Unusual commodities or
mineralisation types (e.g., submarine nodules)
may warrant disclosure of detailed information.
Drill type (e.g., core, reverse circulation, open‐hole
hammer, rotary air blast, auger, Bangka, sonic,
etc) and details (e.g., core diametre, triple or
standard tube, depth of diamond tails,
facesampling
bit or other type, whether core is
oriented and if so, by what method, etc).
Method of recording and assessing core and
chip sample recoveries and results assessed.
Measures taken to maximise sample recovery
and ensure representative nature of the
samples.
Whether a relationship exists between sample
recovery and grade and whether sample bias
may have occurred due to preferential loss/gain
of fine/coarse material.
Samples weighing up to several kilograms were taken.
Whether core and chip samples have been
geologically and geotechnically logged to a level
of detail to support appropriate Mineral
Resource estimation, mining studies and
metallurgical studies.
Whether logging is qualitative or quantitative in
nature. Core (or costean, channel, etc)
photography.
Not Applicable.
The purpose of the rock chip samples was to establish the
tenor of any mineralisation visible in outcrop. Therefore,
the samples are biased towards mineralised samples. This
is appropriate for this type of work.
Sampling
Techniques
Drilling
techniques
Drill sample
recovery
Logging
Sub‐sampling
techniques and
The total length and percentage of the relevant
intersections logged.
If core, whether cut or sawn and whether
quarter, half or all core taken.
Not Applicable.
Not Applicable.
Not Applicable.
Not Applicable.
Rock chip sample type, lithology, veining, alteration,
mineralisation and weathering is logged. Where visible
gold or other mineralisation is observed it is not taken as
a substitute for appropriate laboratory analysis.
Laboratory assays will be reported when they are
received and interpreted.
Not Applicable.
Not Applicable.
Page 7 of 10 | ABN 43 650 398 897
Level 7, 1 Margaret Street Sydney
www.legacyminerals.com.au
ASX: LGM
sample
preparation
Quality of
assay data and
laboratory
tests
Verification of
sampling and
assaying
Location of
data points
Data spacing
and
distribution
If non‐core, whether riffled, tube sampled,
rotary split, etc and whether sampled wet or
dry.
For all sample types, the nature, quality and
appropriateness of the sample preparation
technique.
Quality control procedures adopted for all
subsampling stages to maximise representivity of
samples.
Measures taken to ensure that the sampling is
representative of the in-situ material collected,
including for instance results for field
duplicate/second‐half sampling.
Whether sample sizes are appropriate to the
grain size of the material being sampled.
Not Applicable.
The nature, quality and appropriateness of the
assaying and laboratory procedures used and
whether the technique is considered partial or
total.
For geophysical tools, spectrometres, handheld
XRF instruments, etc, the parametres used in
determining the analysis including instrument
make and model, reading times, calibrations
factors applied and their derivation, etc.
Nature of quality control procedures adopted
(e.g., standards, blanks, duplicates, external
laboratory checks) and whether acceptable
levels of accuracy (i.e., lack of bias) and precision
have been established.
The verification of significant intersections by
either independent or alternative company
personnel.
Not Applicable.
The use of twinned holes.
Documentation of primary data, data entry
procedures, data verification, data storage
(physical and electronic) protocols.
Not Applicable.
Primary assay data will be captured using Datashed
software and includes geological logging, sample data
and QA/QC information. This data, together with the
assay data, is stored both locally and entered into LGM
online database. All historical data has been entered
digitally by previous explorers and verified internally by
LGM.
Discuss any adjustment to assay data.
No adjustments have been required.
Accuracy and quality of surveys used to locate
drill holes (collar and down‐hole surveys),
trenches, mine workings and other locations
used in Mineral Resource estimation.
Specification of the grid system used.
Quality and adequacy of topographic control.
Data spacing for reporting of Exploration
Results.
Whether the data spacing and distribution is
sufficient to establish the degree of geological
and grade continuity appropriate for the
Mineral Resource and Ore Reserve estimation
procedure(s) and classifications applied. Whether
sample compositing has been applied.
Whether sample compositing has been applied.
Samples were located with a handheld GPS.
Not Applicable.
Laboratory QC procedures for rock sample assays involve
the use of internal certified reference material as assay
standards, along with blanks and duplicates.
Not appropriate for this stage of exploration.
The size of samples for the rock chips is appropriate for
this stage of exploration.
Not Applicable.
Quality control procedures for assays were followed via
internal laboratory protocols. Accuracy and precision are
within acceptable limits.
Significant assays have not been verified by independent
or alternative companies. This is not required at this
stage of exploration.
The grid system used is GDA94, MGA Zone 55.
Not Applicable.
Not Applicable.
Not Applicable.
No mineral resource or reserve calculation has been
applied
No compositing has been applied to the exploration
results.
Page 8 of 10 | ABN 43 650 398 897
Level 7, 1 Margaret Street Sydney
www.legacyminerals.com.au
ASX: LGM
Orientation of
data in relation
to geological
structure
Sample
security
Whether the orientation of sampling achieves
unbiased sampling of possible structures and
the extent to which this is known, considering
the deposit type.
If the relationship between the drilling
orientation and the orientation of key
mineralised structures is considered to have
introduced a sampling bias, this should be
assessed and reported if material.
The measures taken to ensure sample security.
Not Applicable.
Not Applicable.
All samples are bagged into tied calico bags, before being
grouped into polyweave bags and transported to ALS
Minerals Laboratory in Orange by Legacy Minerals
personnel. All sample submissions are documented via
ALS tracking system with results reported via email.
Sample pulps are returned to site and stored for an
appropriate length of time.
Audits or
reviews
The results of any audits or reviews of sampling
techniques and data.
The Company has in place protocols to ensure data
security.
This is not material for these Exploration Results.
Section 2 Reporting of Exploration Results
(Criteria in this section apply to all succeeding section)
Criteria
Mineral
Tenement and
Land Status
Exploration
Done by Other
Parties
Geology
Drill hole
Information
JORC Code Explanation
Commentary
Type, name/reference number, location and
ownership including agreements or material
issues with third parties including joint ventures,
partnerships, overriding royalties, native title
interests, historical sites, wilderness or national
park and environmental settings.
The Bauloora Project is comprised of EL8994. The
license is owned 100% by Legacy Minerals Pty Ltd
(a fully owned subsidiary of Legacy Minerals
Holdings Limited). There are no royalties or
encumbrances over the tenement areas.
The security of the tenure held at the time of
reporting along with any known impediments to
obtaining a licence to operate in the area.
Acknowledgment and appraisal of exploration
by other parties.
Deposit type, geological setting and style of
mineralisation
A summary of all information material to the
understanding of the exploration results
including tabulation of the following
information for all Material drill holes:
• Easting and northing of the drill hole collar
•Elevation or RL (Reduced Level – elevation
above sea level in metres) of the drill hole collar
• Dip and azimuth of the hole
• Down hole length and interception depth
• Hole length
If the exclusion of this information is justified on the basis
that the information is not Material and this exclusion
does not detract from the understanding of the report,
the Competent Person should clearly explain why this is
the case.
The land is primarily freehold land. There are no
native title interests in the license area.
Reports on historical exploration can be found in
the Company’s Prospectus dated 28 July 2021.
Known mineralisation at the Bauloora project sits
within the Silurian Frampton Volcanics and
Devonian Bethungra Formation, Cowcumbala
Rhyolite and Deep Gully Creek Conglomerate.
The project is considered prospective for lowsulphidation epithermal style gold-silver and
base-metal mineralisation.
Not Applicable.
Not Applicable.
Page 9 of 10 | ABN 43 650 398 897
Level 7, 1 Margaret Street Sydney
www.legacyminerals.com.au
ASX: LGM
Data
aggregation
methods
Relationship
between
mineralisation
widths and
intercept
lengths
Diagrams
Balanced
Reporting
Other
substantive
exploration
data
Further Work
In reporting Exploration Results, weighting
averaging techniques, maximum and/or
minimum grade truncations (e.g., cutting of high
grades) and cut‐off grades are usually Material
and should be stated.
Where aggregated intercepts incorporate short
lengths of high-grade results and longer lengths
of low-grade results, the procedure used for such
aggregation should be stated and some typical
examples of such aggregations should be shown
in detail.
The assumptions used for any reporting of
metal equivalent values should be clearly
stated.
These relationships are particularly important in
the reporting of exploration results. If the
geometry of the mineralisation with respect to
the drill hole angle is known, its nature should
be reported. If it is not known and only the down
hole lengths are reported, there should be a
clear statement to this effect.
Appropriate maps and sections (with scales) and
tabulations of intercepts should be included for
any significant discovery being reported. These
should include, but not be limited to a plane
view of drill hole collar locations and
appropriate sectional views.
Where comprehensive reporting of all
Exploration Results is not practical,
representative reporting of both low and high
grades and/or widths should be practiced to
avoid misleading reporting of Exploration
Results.
Not applicable.
Other exploration data, if meaningful and
material, should be reported including (but not
limited to): geological observation; geophysical
survey results; geochemical survey results; bulk
samples – size and method of treatment;
metallurgical test results; bulk density,
groundwater, geotechnical and rock
characteristics; potential deleterious or
contaminating substances.
The nature and scale of planned further work
(e.g., tests for lateral extensions or depth
extensions or large – scale step – out
drilling). Diagrams clearly highlighting the areas
of possible extensions, including the main
geological interpretations and future drilling
areas, provided this information is not
commercially sensitive.
All material or meaningful data collected has
been reported.
Not applicable.
Not applicable.
Not applicable.
Refer to Figures in body of text.
A prospect location map are shown in the
Company’s Prospectus dated 28 July 2021 and
within the body of this report.
Not applicable.
All assay results have been reported.
Reports on historical exploration can be found in
the Company’s Prospectus dated 28 July 2021.
See body of report.
See figures in body of report.
Further exploration is discussed in the
announcement and will be planned based on
ongoing geochemical and geophysical results and
geological assessment of prospectivity.
Page 10 of 10 | ABN 43 650 398 897
Level 7, 1 Margaret Street Sydney
www.legacyminerals.com.au
ASX: LGM
Share your feedback
Discover