Highlights
•
Initial metallurgical testwork, using a relatively simple flotation process, has
demonstrated exceptionally high recoveries for gold, silver, copper, lead and zinc
•
Indicates mineralisation at the Mt Felstead Prospect is amenable to low-cost industry
standard flotation beneficiation and potential for high-quality concentrate product.
•
Samples were taken from drill holes 240m apart giving confidence to the representative
recoveries of the Mt Felstead Prospect epithermal style mineralisation.
Cumulative Recoveries
•
Cumulative rougher concentrates 1-3 returned recoveries of:
Silver
Gold
Semi-Massive Sulphides
99.6%
93.6%
Massive Sulphides
98.1%
Veined
92.9%
Copper
Lead
Zinc
99.1%
98.9%
99.2%
84.1%
95.5%
98.1%
98.4%
87.1%
89.3%
89.4%
94.5%
Cumulative Concentrate
•
Cumulative rougher concentrates 1-3 returned grades of:
Silver Concentrate
Gold Concentrate
Lead Concentrate
Zinc Concentrate
Semi-Massive Sulphides
1,555g/t
13.2g/t
41.8%
21.1%
Massive Sulphides
184g/t
14.5.g/t
24.2%
33.0%
Veined
130g/t
13.0g/t
17.3%
41.5%
Future Drilling Planned
•
Further drilling is planned across the 100% owned Bauloora Project following the
completion of a large-scale soil program and successful drill campaign early this year.
ABN 43 650 398 897
Level 7, 1 Margaret Street Sydney
ASX: LGM
Page 1 of 21
www.legacyminerals.com.au
Legacy Minerals Holdings Limited (ASX: LGM, “LGM”, “the Company” or “Legacy Minerals”)
is pleased to provide an update on the exploration program at the Mt Felstead Prosect, at the
Bauloora Project, New South Wales.
Management Comment
Legacy Minerals’ Managing Director, Christopher Byrne said:
“Off the back of the high-grade gold-silver and base metal drilling results at Mt Felstead
Prospect it is exciting to build on the potential of Bauloora with these outstanding
metallurgical recoveries. The metallurgical testing gives Legacy Minerals evidence that metals
of value can be recovered through an economically viable industry standard processing route.
Work is ongoing across the wider Bauloora Project the soil geochemistry program underway.
Legacy Minerals is fully funded to drill test emerging targets across the project, and we look
forward to keeping our shareholders updated on the results.”
Metallurgical Testing
Three metallurgical samples were analysed at ALS Ltd (Perth) which included separate
representative samples of massive, semi-massive and veined sulphide mineralisation from
the Mt Felstead Prospect. The testing looked to determine the mineral grades (cumulative
grade) and recoveries (cumulative recovery) of these samples. The cumulative recovery is the
percentage of metals recovered from a concentrate that has gone through stages of flotation
and the cumulative concentrate is the total amount of contained metals in a sample that have
been recovered through the floatation process.
The flotation process used is a standard mineral beneficiation process used for processing
minerals. It involves circuits of crushing and grinding whereby the minerals of value are
concentrated and separated from minerals of no value. This separation is done by taking
advantage of mineral hydrophobicity differences. Rougher flotation is usually the first stage
of the flotation process where the maximum amount of the valuable mineral is concentrated
at a coarse particle size.
Three composite bulk samples consisting of a total of 111.5kg of reverse circulation
percussion (RC) material from drill holes BM007 (BKF2938: 149-150m and BKF2939: 152153m) and BM008 (BKF2937: 149-150m) were submitted to ALS Metallurgical Services in
Perth for initial bench top flotation test work (Appendix 1). These three samples were
collected from the massive sulphide, semi-massive sulphide, and vein-hosted mineralisation
present at the Mt Felstead Prospect. The parameters of initial test work included grind size of
80% passing 75μm and four-stage rougher stage flotation using standard reagents producing
a bulk concentrate. The entire test work data is provided in Appendix 1, however the
cumulative rougher concentrate and grades for 1-3 flotations are presented in the body of
the report.
Page 2 of 21 | ABN 43 650 398 897
Level 7, 1 Margaret Street Sydney
www.legacyminerals.com.au
ASX: LGM
Table 1: Cumulative gold recovery or rougher concentrate 1-3
Assay Head Grade
Recovery
Au Concentrate Grade
BKF2937 (Semi-Massive)
5.20g/t
93.6%
13.2g/t
BKF2938 (Massive)
9.88g/t
84.1%
14.5.g/t
BKF2939 (Veined)
1.47g/t
87.1%
13.0g/t
Table 2: Cumulative silver recovery or rougher concentrate 1-3
Assay Head Grade
Recovery
Ag Concentrate Grade
BKF2937 (Semi-Massive)
473g/t
99.6%
1,555g/t
BKF2938 (Massive)
99g/t
98.1%
184g/t
BKF2939 (Veined)
15g/t
92.9%
130g/t
Table 3: Cumulative zinc recovery or rougher concentrate 1-3
Assay Head Grade
Recovery
Zn Concentrate Grade
BKF2937 (Semi-Massive)
6.71%
99.2%
21.1%
BKF2938 (Massive)
17.2%
98.4%
33.0%
BKF2939 (Veined)
4.64%
94.5%
41.5%
Table 4: Cumulative lead recovery or rougher concentrate 1-3
Assay Head Grade
Recovery
Pb Concentrate Grade
BKF2937 (Semi-Massive)
12.8%
98.9%
41.8%
BKF2938 (Massive)
12.6%
98.1%
24.2%
BKF2939 (Veined)
2.02%
89.4%
17.3%
Page 3 of 21 | ABN 43 650 398 897
Level 7, 1 Margaret Street Sydney
www.legacyminerals.com.au
ASX: LGM
Figure 1: Mt Felstead Prospect rougher flotation concentration stages one to four (BKF2939)
This preliminary flotation test work produced a bulk concentrate containing gold, silver, zinc
and lead mineralisation in one product (Figure 1, photos 1 to 4). The Company is investigation
the potential that separate concentrate products for the minerals can be produced using
gravity separation, leaching and the same floatation processes used here, where commonly
an initial lead flotation stage is followed by a dedicated zinc flotation stage. This will be the
subject of further metallurgical tests as the project develops.
Page 4 of 21 | ABN 43 650 398 897
Level 7, 1 Margaret Street Sydney
www.legacyminerals.com.au
ASX: LGM
Figure 2: Mt Felstead Prospect test-work drill hole locations.
Page 5 of 21 | ABN 43 650 398 897
Level 7, 1 Margaret Street Sydney
www.legacyminerals.com.au
ASX: LGM
Next Stages at the Bauloora Project
Soil geochemistry surveys are currently underway across the northern extent of the Bauloora
anomalous gold zone 1. Once completed, the results from the soil program, geological
mapping conducted, and recently completed gradient array induced polarisation, will be
analysed and drill targets refined for testing this year.
Sample 3933: Colloform-crustiform
chalcedony (quartz)-carbonateadularia vein
Sample 3933: Cockade textured
breccia with colloform-crustiform
quartz-carbonate-adularia banding
Sample ID 2934: Colloformcrustiform quartz-carbonate vein
within argillic altered dacite
Figure 3: Soil sampling survey area, rock sample locations and drilling highlights
1
ASX LGM 23 June 2022: Large Soil Campaign Underway at Bauloora Epithermal Project
Page 6 of 21 | ABN 43 650 398 897
Level 7, 1 Margaret Street Sydney
www.legacyminerals.com.au
ASX: LGM
About the Bauloora Project – One of NSW’s Largest Epithermal Systems
•
•
The Project covers 27km2 of hydrothermal alteration and mineralisation as is one of the
largest epithermal systems in NSW 2.
The Mt Felstead Prospect covers less than 2% of this epithermal alteration footprint
area and the metallurgical testing completed by the Company is the first modern work
done on the project area.
Figure 4: Bauloora ‘Anomalous Gold Zone’
2
Company’s Prospectus dated 28 July 2021 lodged 9 September 2021 (ASX: LGM)
Page 7 of 21 | ABN 43 650 398 897
Level 7, 1 Margaret Street Sydney
www.legacyminerals.com.au
ASX: LGM
Approved by the Board of Legacy Minerals Holdings Limited.
For more information:
Chris Byrne
CEO & Managing Director
chris.byrne@legacyminerals.com.au
+61 (0) 499 527 547
Victoria Humphries
Media & Investor Relations
victoria@nwrcommunications.com.au
+61 (0) 431 151 676
DISCLAIMER AND PREVIOUSLY REPORTED INFORMATION
Information in this announcement is extracted from reports lodged as market announcements referred to above
and available on the Company’s website https://legacyminerals.com.au/. The Company confirms that it is not
aware of any new information that materially affects the information included in the original market
announcement and that all material assumptions and technical parameters underpinning the estimates in the
relevant market announcement continue to apply and have not materially changed.
This announcement contains certain forward-looking statements. Forward looking statements are only
predictions and are subject to risks, uncertainties and assumptions which are outside of the control of Legacy
Minerals Holdings Limited (LGM). These risks, uncertainties and assumptions include commodity prices,
currency fluctuations, economic and financial market conditions, environmental risks and legislative, fiscal or
regulatory developments, political risks, project delay, approvals and cost estimates. Actual values, results or
events may be materially different to those contained in this announcement. Given these uncertainties, readers
are cautioned not to place reliance on forward-looking statements. Any forward-looking statements in this
announcement reflect the views of LGM only at the date of this announcement. Subject to any continuing
obligations under applicable laws and ASX Listing Rules, LGM does not undertake any obligation to update or
revise any information or any of the forward-looking statements in this announcement to reflect changes in
events, conditions or circumstances on which any forward-looking statements is based.
COMPETENT PERSON’S STATEMENT
The information in this report that relates to Exploration Targets, Exploration Results, Mineral Resources or Ore
Reserves is based on information compiled by Thomas Wall, a Competent Person who is a Member of the
Australian Institute of Geoscientists. Mr Wall is the Technical Director and a full-time employee of Legacy
Minerals Pty Limited, the Company’s wholly owned subsidiary, and a shareholder of the Company. Mr Wall has
sufficient experience that is relevant to the style of mineralisation and type of deposit under consideration and
to the activity being undertaken to qualify as a Competent Person as defined in the 2012 edition of the
Australasian Code for Reporting of Exploration Results, Mineral Resources and Ore Reserves. Mr Wall consents
to the inclusion in the report of the matters based on his information in the form and context in which it appears
in this announcement.
REFERENCED DOCUMENTS
Company’s Prospectus dated 28 July 2021 lodged 9 September 2021 (ASX: LGM)
ASX LGM 23 June 2022: Large Soil Campaign Underway at Bauloora Epithermal Project
Page 8 of 21 | ABN 43 650 398 897
Level 7, 1 Margaret Street Sydney
www.legacyminerals.com.au
ASX: LGM
About Legacy Minerals
Legacy Minerals is an ASX listed public company that has been involved in the acquisition and
exploration of gold, copper, and base-metal projects in the Lachlan Fold Belt since 2017. The
Company has six wholly owned and unencumbered tenements that present significant discovery
opportunities for shareholders.
Au-Cu (Pb-Zn) Cobar (EL8709, EL9256)
Au Harden (EL8809, EL9257)
Undrilled targets next door to the Peak Gold Mines with
several priority geophysical anomalies Late time AEM
conductors, IP anomaly, and magnetic targets
Geochemically anomalous - gold in lag up to 1.55g/t Au.
Large historical high-grade quartz-vein gold
mineralisation open along strike and down plunge.
Significant drill intercepts include 3.6m at 21.7g/t Au
116m and 2m at 17.17g/t Au from 111m.
Au-Ag Bauloora (EL8994)
A 27km hydrothermal alteration area containing lowsulphidation epithermal-style gold silver targets.
Historical bonanza grades at the Mt Felstead Prospect
included face sampling up to 3,701g/t Ag, 6.9g/t Au,
29% Pb, 26% Zn, and 6.4% Cu.
2
Au-Cu Fontenoy (EL8995)
The Project exhibits a greater than 8km long zone of Au
and Cu anomalism defined in soil sampling and drilling.
Significant drill intercepts include 79m at 0.27% Cu from
1.5m with numerous untested anomalies along the 8km
strike length.
Cu-Au Rockley (EL8296)
Sn-Ni-Cu Mulholland (EL9330)
Prospective for porphyry Cu-Au and situated in the
Macquarie Arc Ordovician host rocks the project
contains historic high-grade copper mines that graded
up to 23% Cu.
Associated polymetallic mineralisation. There are
several tin and nickel occurrences in the project area
with trends up to 2.6km defined in drilling. Significant
drill intercepts include 44m at 0.45% Ni.
Figure 5: Legacy Minerals Tenements, NSW, Australia
ABN 43 650 398 897
Level 7, 1 Margaret Street Sydney
ASX: LGM
Page 9 of 21
www.legacyminerals.com.au
Appendix 1 – Rougher Flotation Testwork: Reagent Scheme & Results
ROUGHER FLOTATION TESTWORK : REAGENT SCHEME & RESULTS
PROJECT
CLIENT
SAMPLE ID
TEST No.
WATER
GRIND SIZE
PULP
DENSITY
DATE
A23537
LEGACY MINERALS HOLDINGS LTD
MET 001
BKF2937
PERTH TAP
P80 :
75
µm
30-35% solids
JUN-2022
REAGENT SCHEME PER CYCLE :
Operation
Condition
Time
Eh
pH
(mV)
7.7
+178
10.5
10.5
-5
-32
Lime
(mins)
PAX
(g)
(g/t)
1.02
50
W24
Flotatio
n
Frother
Time
(drops)
(mins)
2
2
Conditioning
Con 1
1
Con 2
1
10.5
-48
Con 3
1
10.5
-54
0.16
20
Con 4
1
10.5
-54
0.25
10
1
5
1.63
110
3
12
TOTAL
0.20
30
2
3
ASSAY DATA
Assays
Product
Mass
Ag
Au
Cu
Pb
S
Zn
Rghr Con 1
(g)
424.0
(ppm)
1910
(g/t)
16.0
(%)
3.82
(%)
51.3
(%)
19.9
(%)
16.8
Rghr Con 2
145.5
898
7.86
3.29
23.8
23.8
34.8
Rghr Con 3
46.6
382
4.38
1.70
11.6
11.9
17.4
Rghr Con 4
39.8
68
2.16
0.32
2.75
1.48
1.46
Tail
Calc. Head
Grade
Assay Head
Grade
1344.9
<2
0.35
<0.01
0.13
0.04
0.03
481
4.34
1.10
13.0
6.28
6.55
473
5.20
1.12
12.8
6.27
6.71
2000.9
Page 10 of 21 | ABN 43 650 398 897
Level 7, 1 Margaret Street Sydney
www.legacyminerals.com.au
ASX: LGM
Distribution (%)
Product
Mass
Ag
Au
Cu
Pb
S
Zn
Rghr Con 1
21.2
84.1
78.1
73.7
83.5
67.1
54.4
Rghr Con 2
7.27
13.6
13.2
21.8
13.3
27.6
38.7
Rghr Con 3
2.33
1.85
2.35
3.61
2.08
4.41
6.19
Rghr Con 4
1.99
0.28
0.99
0.58
0.42
0.47
0.44
Tail
67.2
0.14
5.42
0.31
0.67
0.43
0.31
TOTAL
100.0
100.0
100.0
100.0
100.0
100.0
100.0
CUMULATIVE CON GRADES
Assays
Product
Mass
Ag
Au
Cu
Pb
S
Zn
Rghr Con 1
(g)
424.0
(ppm)
1910
(g/t)
16.0
(%)
3.82
(%)
51.3
(%)
19.9
(%)
16.8
Rghr Con 1-2
569.6
1651
13.9
3.68
44.3
20.9
21.4
Rghr Con 1-3
616.2
1555
13.2
3.53
41.8
20.2
21.1
Rghr Con 1-4
656.0
1465
12.5
3.34
39.4
19.1
19.9
Cu
Pb
S
Zn
CUMULATIVE RECOVERY
Recovery (%)
Product
Mass
Ag
Au
Rghr Con 1
Rghr Con 1-2
21.2
84.1
78.1
73.7
83.5
67.1
54.4
28.5
97.7
91.2
95.5
96.8
94.7
93.1
Rghr Con 1-3
30.8
99.6
93.6
99.1
98.9
99.1
99.2
Rghr Con 1-4
32.8
99.9
94.6
99.7
99.3
99.6
99.7
Page 11 of 21 | ABN 43 650 398 897
Level 7, 1 Margaret Street Sydney
www.legacyminerals.com.au
ASX: LGM
ROUGHER FLOTATION TESTWORK : REAGENT SCHEME & RESULTS
PROJECT
CLIENT
SAMPLE ID
TEST No.
WATER
GRIND SIZE
PULP DENSITY
DATE
A23537
LEGACY MINERALS
HOLDINGS LTD
MET 002
BKF2938
PERTH TAP
P80 :
30-35% solids
JUN-2022
75
µm
REAGENT SCHEME PER CYCLE :
Operation
Condition
Time
Eh
pH
Lime
PAX
(g)
(g/t)
(mV)
(mins)
W24
Flotation
Frother
Time
(drops)
(mins)
2
2
7.1
+75
Conditioning
Con 1
1
10.5
10.5
-29
-34
1.05
50
Con 2
1
10.5
-27
0.14
30
2
Con 3
1
10.5
39
0.14
20
3
Con 4
1
10.5
-35
0.11
10
1
5
1.44
110
3
12
TOTAL
ASSAY DATA
Assays
Product
Mass
Ag
Au
Cu
Pb
S
Zn
Rghr Con 1
(g)
401.0
(ppm)
322
(g/t)
24.1
(%)
0.83
(%)
46.8
(%)
21.1
(%)
26.3
Rghr Con 2
417.8
104
8.44
1.02
10.4
23.9
44.4
Rghr Con 3
190.9
70
7.67
0.98
7.17
12.5
22.2
Rghr Con 4
118.3
26
4.24
0.34
2.79
2.29
3.59
Tail
Calc. Head
Grade
Assay Head
Grade
871.3
<1
2.60
<0.01
0.17
0.06
0.12
95
8.71
0.50
12.5
10.6
16.9
99
9.88
0.51
12.6
10.7
17.2
Product
1999.3
Distribution (%)
Page 12 of 21 | ABN 43 650 398 897
Level 7, 1 Margaret Street Sydney
www.legacyminerals.com.au
ASX: LGM
Mass
Ag
Au
Cu
Pb
S
Zn
Rghr Con 1
20.1
68.2
55.5
33.6
75.2
40.0
31.1
Rghr Con 2
20.9
22.9
20.2
43.0
17.4
47.2
54.8
Rghr Con 3
9.55
7.1
8.40
18.9
5.48
11.3
12.5
Rghr Con 4
5.92
1.62
2.88
4.06
1.32
1.28
1.25
Tail
43.6
0.23
13.0
0.44
0.59
0.25
0.31
TOTAL
100.0
100.0
100.0
100.0
100.0
100.0
100.0
CUMULATIVE CON GRADES
Assays
Product
Rghr Con 1
Mass
Ag
Au
Cu
Pb
S
Zn
(g)
401.0
(ppm)
322
(g/t)
24.1
(%)
0.83
(%)
46.8
(%)
21.1
(%)
26.3
Rghr Con 1-2
818.8
211
16.1
0.93
28.2
22.5
35.5
Rghr Con 1-3
1009.7
184
14.5
0.94
24.2
20.6
33.0
Rghr Con 1-4
1128.0
168
13.4
0.87
22.0
18.7
29.9
Pb
S
Zn
CUMULATIVE RECOVERY
Recovery (%)
Product
Mass
Ag
Au
Cu
Rghr Con 1
Rghr Con 1-2
20.1
68.2
55.5
33.6
75.2
40.0
31.1
41.0
91.1
75.7
76.6
92.6
87.2
85.9
Rghr Con 1-3
50.5
98.1
84.1
95.5
98.1
98.5
98.4
Rghr Con 1-4
56.4
99.8
87.0
99.6
99.4
99.8
99.7
Page 13 of 21 | ABN 43 650 398 897
Level 7, 1 Margaret Street Sydney
www.legacyminerals.com.au
ASX: LGM
ROUGHER FLOTATION TESTWORK : REAGENT SCHEME & RESULTS
PROJECT
CLIENT
SAMPLE ID
TEST No.
WATER
GRIND SIZE
PULP
DENSITY
DATE
A23537
LEGACY MINERALS
HOLDINGS LTD
MET 003
BKF2939
PERTH TAP
P80 :
75
µm
30-35% solids
JUN-2022
REAGENT SCHEME PER CYCLE :
Operation
Condition
Time
Eh
pH
(mV)
7.7
+134
10.5
10.5
(mins)
Lime
PAX
(g)
(g/t)
-39
-49
1.14
50
0.53
Conditioning
Con 1
1
Con 2
1
10.5
-58
Con 3
1
10.5
-54
Con 4
1
10.5
-58
TOTAL
0.05
W24
Flotation
Frother
Time
(drops)
(mins)
2
2
30
2
20
3
0.14
10
1
5
1.86
110
3
12
ASSAY DATA
Assays
Product
Mass
Ag
Au
Cu
Pb
S
Zn
Rghr Con 1
(g)
125.1
(ppm)
161
(g/t)
17.5
(%)
0.64
(%)
21.7
(%)
26.3
(%)
44.6
Rghr Con 2
49.0
95
7.77
0.40
11.8
23.0
42.7
Rghr Con 3
33.0
65
3.76
0.26
8.96
15.2
27.9
Rghr Con 4
42.0
28
2.86
0.10
3.88
3.40
5.71
Tail
Calc. Head
Grade
Assay Head
Grade
1743.6
<1
0.16
<0.01
0.15
0.09
0.15
15
1.55
0.06
2.01
2.62
4.56
15
1.47
0.05
2.02
2.63
4.64
Product
1992.7
Distribution (%)
Page 14 of 21 | ABN 43 650 398 897
Level 7, 1 Margaret Street Sydney
www.legacyminerals.com.au
ASX: LGM
Mass
Ag
Au
Cu
Pb
S
Zn
Rghr Con 1
6.28
69.5
70.8
66.1
67.6
63.0
61.4
Rghr Con 2
2.46
16.1
12.3
16.2
14.4
21.6
23.0
Rghr Con 3
1.66
7.4
4.01
7.08
7.37
9.61
10.1
Rghr Con 4
2.11
4.06
3.88
3.47
4.06
2.74
2.64
Tail
87.5
3.01
9.02
7.20
6.52
3.01
2.88
TOTAL
100.0
100.0
100.0
100.0
100.0
100.0
100.0
CUMULATIVE CON GRADES
Assays
Product
Mass
Ag
Au
Cu
Pb
S
Zn
Rghr Con 1
(g)
125.1
(ppm)
161
(g/t)
17.5
(%)
0.64
(%)
21.7
(%)
26.3
(%)
44.6
Rghr Con 1-2
174.1
142
14.8
0.57
18.9
25.4
44.1
Rghr Con 1-3
207.1
130
13.0
0.52
17.3
23.8
41.5
Rghr Con 1-4
249.1
113
11.3
0.45
15.1
20.3
35.5
Pb
S
Zn
CUMULATIVE RECOVERY
Recovery (%)
Product
Mass
Ag
Au
Cu
Rghr Con 1
Rghr Con 1-2
6.3
69.5
70.8
66.1
67.6
63.0
61.4
8.7
85.5
83.1
82.3
82.1
84.6
84.4
Rghr Con 1-3
10.4
92.9
87.1
89.3
89.4
94.3
94.5
Rghr Con 1-4
12.5
97.0
91.0
92.8
93.5
97.0
97.1
Page 15 of 21 | ABN 43 650 398 897
Level 7, 1 Margaret Street Sydney
www.legacyminerals.com.au
ASX: LGM
Appendix 2 – JORC Code, 2021 Edition Table 1
Section 1 Sampling Techniques and Data
Criteria
JORC Code Explanation
Commentary
Nature and quality of sampling (e.g., cut
channels, random chips, or specific specialised
industry standard measurement tools
appropriate to the minerals under investigation,
such as down hole gamma sondes, or handheld
XRF instruments, etc). These examples should not
be taken as limiting the broad meaning of
sampling.
RC Sampling: RC drilling and sampling was undertaken by
Durock Drilling Pty Ltd. All samples from the RC drilling
are taken as 1m samples for laboratory assay. Samples
are collected using cone or riffle splitter. Samples were
mostly dry and sample loss was minimal. Geological
logging of RC chips is completed at site with
representative chips being stored in drill chip trays.
Magnetic susceptibility was recorded from the green
bulk bag for each meter by a KT-10 mag sus meter.
RC Sampling: Samples are taken on a one metre basis
and collected using uniquely numbered calico bags. The
remaining material for that metre is collected and stored
in a green plastic bag marked with that specific metre
interval. The cyclone is cleaned with compressed air after
each plastic and calico sample bag is removed. If wet
sample or clays are encountered then the cyclone is
opened and cleaned manually and with the aid of a
compressed air gun. A blank sample is inserted at the
beginning of each hole, and a duplicate sample is taken
every 50th sample. A certified sample standard is also
added according to geology, but at no more than 1:50
samples.
Include reference to measures taken to ensure
sample representivity and the appropriate
calibration of any measurement tools or
systems used.
Geological logging of RC chips is completed at site with
representative chips being stored in drill chip trays.
Downhole surveys of dip and azimuth are conducted
using a single shot camera every 30m, and using a
downhole Gyro when required, to detect deviations of
the hole from the planned dip and azimuth. The drill‐hole
collar locations are recorded using a hand‐held GPS,
which has an accuracy of +/‐ 5m. All drill‐hole collars may
be surveyed to a greater degree of accuracy using a
certified surveyor at a later date.
Sampling
Techniques
An Olympus Vanta pXRF is used to systematically analyse
the RC sample onsite. One reading is taken per metre
with field calibration of the pXRF instrument using
standards periodically performed (usually daily).
Intervals undergoing metallurgical tests had the bulk
green plastic bags for each metre submitted to ALS
Orange for later transport to Perth for metallurgical tests
to be conducted.
Aspects of the determination of mineralisation
that are Material to the Public Report.
In cases where ‘industry standard’ work has
been done this would be relatively simple (e.g.
‘reverse circulation drilling was used to obtain 1
m samples from which 3 kg was pulverised to
produce a 30 g charge for fire assay’). In other
cases more explanation may be required, such
as where there is coarse gold that has inherent
sampling problems. Unusual commodities or
mineralisation types (e.g. submarine nodules)
The handheld pXRF results are only used for preliminary
assessment of element compositions, prior to the receipt
of assay results from the certified laboratory.
Mineralisation in the holes were geologically logged and
the magnetic susceptibility was recorded from the calico
bag for each meter by a KT-10 mag sus meter.
Reverse circulation was used to obtain 1m samples from
which 1-5kg was pulverised to produce a 50gr charge for
fire assay by ALS Orange Laboratory and four acid ICP
analysis, ME-MS61 by ALS Brisbane or other ALS lab.
Page 16 of 21 | ABN 43 650 398 897
Level 7, 1 Margaret Street Sydney
www.legacyminerals.com.au
ASX: LGM
Drilling
techniques
Drill sample
recovery
Logging
may warrant disclosure of detailed information.
Drill type (e.g. core, reverse circulation, open‐
hole hammer, rotary air blast, auger, Bangka,
sonic, etc) and details (e.g. core diameter, triple
or standard tube, depth of diamond tails, face
sampling bit or other type, whether core is
oriented and if so, by what method, etc).
Method of recording and assessing core and
chip sample recoveries and results assessed.
Measures taken to maximise sample recovery
and ensure representative nature of the
samples.
Whether a relationship exists between sample
recovery and grade and whether sample bias
may have occurred due to preferential loss/gain
of fine/coarse material.
Whether core and chip samples have been
geologically and geotechnically logged to a level
of detail to support appropriate Mineral
Resource estimation, mining studies and
metallurgical studies.
Whether logging is qualitative or quantitative in
nature. Core (or costean, channel, etc)
photography.
The total length and percentage of the relevant
intersections logged.
If core, whether cut or sawn and whether
quarter, half or all core taken.
If non‐core, whether riffled, tube sampled,
rotary split, etc and whether sampled wet or
dry.
For all sample types, the nature, quality and
appropriateness of the sample preparation
technique.
RC Sampling: The RC drilling uses a 140 mm diameter
face hammer tool. High-capacity air compressors on the
drill rig are used to ensure a continuously sealed and
high‐pressure system during drilling to maximise the
recovery of the drill cuttings, and to ensure chips remain
dry to the maximum extent possible.
RC Sampling: RC samples are visually checked for
recovery, moisture and contamination. Geological
logging is completed at site with representative RC chips
stored in chip trays. Sample weights were recorded on
site using digital scales for each calico sample.
RC Sampling: Samples are collected using cone or riffle
splitter. Geological logging of RC chips is completed at
site with representative chips being stored in drill chip
trays. Sample sizes were monitored and the splitter was
regularly agitated to reduce the potential for sample
contamination
To date, no sample recovery issues have yet been
identified that would impact on potential sample bias in
the competent fresh rocks that host the mineralised
sulphide intervals.
Geological logging is carried out on all drill hole chips
with lithology, alteration, mineralisation, structure and
veining recorded where possible.
Logging of RC samples records lithology, mineralogy,
mineralisation, structures, weathering, colour and other
noticeable features. This is generally qualitative except
for % of sulphides and vein mineral content. Chip trays
are photographed in wet form.
All drill holes are geologically logged in full and
lithogeochemical information is collected by the field XRF
unit. The data relating to the elements analysed is used
to determine further information regarding the rock
composition.
NA
RC samples are collected using a cone or riffle splitter.
Geological logging of RC chips is completed at site with
representative chips being stored in drill chip trays.
RC Sampling: Sample preparation for RC chips follows a
standard protocol. If a sample is wet or damp it is
recorded. Most samples were dry.
Sample preparation will comprise of an industry standard
of drying, jaw crushing and pulverising to -75 microns
(85% passing). Samples are dried, crushed and pulverized
to produce a homogenous representative sub‐sample for
analysis.
Sub‐sampling
techniques and
sample
preparation
Quality control procedures adopted for all
subsampling
stages to maximise representivity of
samples.
Bulk green plastic bags for each metre were submitted to
ALS Orange for later transport to Perth for metallurgical
tests to be conducted.
Quality control procedures include submission of
Certified Reference Materials (standards) and duplicates
with each sample batch. QAQC results are routinely
reviewed to identify and resolve any issues.
RC Sampling: Field QC procedures maximise
representivity of RC samples and involve the use of
Page 17 of 21 | ABN 43 650 398 897
Level 7, 1 Margaret Street Sydney
www.legacyminerals.com.au
ASX: LGM
Measures taken to ensure that the sampling is
representative of the in situ material collected,
including for instance results for field
duplicate/second‐half sampling.
Whether sample sizes are appropriate to the
grain size of the material being sampled.
The nature, quality and appropriateness of the
assaying and laboratory procedures used and
whether the technique is considered partial or
total.
certified reference material as assay standards, along
with blanks, duplicates and barren washes.
RC sampling: Duplicate RC samples are captured using
two separate sampling apertures on the splitter
approximately every 50m. ALS also conduct internal
checks every 20m.
Where possible a Vanta VMW pXRF is also used as a first
pass test and these results are compared with lab
results.
The sample sizes average 3kg and are considered to be
appropriate to correctly represent mineralisation and
associated geology based on: the style of mineralisation,
the thickness and consistency of the intersections and
the sampling methodology.
Samples were stored in a secure location and
transported to the ALS laboratory in Orange, NSW.
Reverse circulation was used to obtain 1m samples
(~20kg) from which 1-5kg was pulverised to produce a
50gr charge for fire assay by ALS Orange Laboratory and
four acid ICP analysis, ME-MS61 by ALS Brisbane or other
ALS lab.
Sample preparation comprised of pulverised (PUL-23)
and where appropriate drying (DRY-21), weigh and
crushing (CRU-31).
The assay methods used were ME-MS61 and Au-AA26
(refer to ALS Fee Schedule 2022). ME-MS61 is a four-acid
digestion with ICP-AES finish. Au-AA25 (50g) is a fire
assay method. The assay methods employed are
considered appropriate for near total digestion.
Quality of
assay data and
laboratory
tests
For geophysical tools, spectrometres, handheld
XRF instruments, etc, the parametres used in
determining the analysis including instrument
make and model, reading times, calibrations
factors applied and their derivation, etc.
Nature of quality control procedures adopted
(e.g. standards, blanks, duplicates, external
laboratory checks) and whether acceptab
Share your feedback
Discover