S2R: Drilling started at Glenlogan Copper-Gold Project, NSW
Released
Released
Announcement PDF
ASX Announcement
18 July 2024
DRILLING STARTED AT GLENLOGAN COPPER-GOLD PROJECT,
NEW SOUTH WALES
Key Points
• First diamond drill hole started at Glenlogan project, NSW
• Designed to test a large buried magnetic anomaly interpreted as a potential
copper-gold porphyry target
• Planned as a >1,000 metre long, flat trajectory hole to optimally test various
potential alteration/mineralised zones around and within the modelled
magnetic target
• First hole anticipated to take ~4 to 6 weeks to complete
S2 Resources Ltd (“S2” or the “Company”) advises that its wholly owned subsidiary, Red Star Resources
Pty Ltd (“Red Star”), has started the first diamond drill hole at its Glenlogan project in the Lachlan Fold
Belt of New South Wales, where it is earning up to an 80% interest from Legacy Minerals (“Legacy”).
The hole, SGLD0001, is designed to test a prominent magnetic anomaly (see Figure 1) modelled as a
vertically oriented columnar body and interpreted to be a potential copper-gold porphyry target (see
S2 ASX announcement of 29 January 2024). The collar of this hole is situated some distance to the
southwest of the centre of the magnetic anomaly and has been designed to drill to the northeast with
a relatively flat trajectory in order to pass through both the vertically oriented magnetic body and any
enveloping alteration and/or mineralised zones surrounding it. It is anticipated that the hole will be
>1,000 metres in length, passing through the modelled core of the magnetic body at a depth of 550 to
600 metres below surface (see Figure 2).
Porphyry copper-gold deposits form in association with porphyritic igneous intrusions and may occur
within the intrusions themselves and/or in adjacent country rocks. The intrusions are often pencil or
finger shaped, with a variety of broadly concentric alteration zones. Mineralisation, if present, usually
takes the form of iron and copper sulphides disseminated throughout the rock and within swarms of
quartz veins, and it may form within and/or outside the porphyry intrusion, in various alteration zones
which may be magnetic (due to the presence of hydrothermal magnetite in association with the
sulphides) or non-magnetic (due to the destruction of primary igneous magnetite by the same
hydrothermal fluids). For this reason, it is important when drilling to ensure all of these scenarios are
tested, which is why this hole is designed in this way, rather than drilling vertically down the axis of the
magnetic body (see Figure 3).
Level 14, 333 Collins Street, Melbourne, VIC 3000, Australia. PO Box 143 Kingsway, WA 6065, Australia
ABN 18 606 128 090 T +61 8 6166 0240 F 61 8 6270 5410 E admin@s2resources.com.au W www.s2resources.com.au
In the event that there is a complex sequence of multiple crosscutting intrusions and/or overprinting
alteration zones, the targeted copper-gold mineralisation could be focused in any one of several
intrusions and/or alteration zones (and not necessarily the magnetic zone), so the first hole may not
necessarily provide a definitive outcome. To anticipate this, a second hole has also been planned,
which will approach the target from a different location and direction in order to test a broader zone
around the magnetic body.
Figure 1. Reduced to the pole magnetic image showing the large central magnetic high surrounded by a magnetic
low, potentially representing a core zone of magnetite alteration with outer magnetite-destructive alteration,
together with collar and panned trajectory of first hole.
Figure 2. Cross section looking west showing the vertical magnetic body and planned trajectory of the first hole.
Level 14, 333 Collins Street, Melbourne, VIC 3000, Australia. PO Box 143 Kingsway, WA 6065, Australia
ABN 18 606 128 090 T +61 8 6166 0240 F 61 8 6270 5410 E admin@s2resources.com.au W www.s2resources.com.au
Figure 3. Schematic cutaway block diagram showing the modelled magnetic column in 3D and where the first
hole is planned to test it (top), and the potential geological basis for the magnetic anomalism – a very simplified
porphyry intrusive system with associated alteration envelopes and mineralised zones.
Level 14, 333 Collins Street, Melbourne, VIC 3000, Australia. PO Box 143 Kingsway, WA 6065, Australia
ABN 18 606 128 090 T +61 8 6166 0240 F 61 8 6270 5410 E admin@s2resources.com.au W www.s2resources.com.au
S2 is mindful and respectful of the communities in which it operates, so given that each hole may take
several weeks to complete, it is using acoustic sheds to minimise the footprint and impact of its
activities (see Figure 4). Inclement weather and poor ground conditions delayed the start of drilling by
a week but the Company was able to install adequate ground protection measures to minimise impact.
Figure 4. Photo of Deepcore’s acoustic shed housing the rig drilling hole SGLD0001, and paddock mats to protect
ground cover.
Target details
As described in the previous ASX announcement (see S2 ASX announcement of 29 January 2024), using
a magnetic susceptibility comparable with Newmont’s Ridgeway copper-gold porphyry deposit, the
magnetic anomaly models as a broadly columnar magnetic body, commencing at a depth of 450-600
metres below surface, with a diameter of approximately 600 metres and a vertical extent of
approximately 1,000 metres.
As detailed in Legacy’s ASX announcement of 9 November 2023, the only deep hole in the area,
DDHCV1, drilled by Mines Exploration over 40 years ago in 1982, is located 1 kilometre to the west of
the anomaly. This hole intersected Devonian sedimentary rocks thought to be occupying a
downfaulted block to the west of the anomaly.
Several relatively shallow percussion holes drilled over 30 years ago in 1992 by Placer Exploration
Limited intersected altered monzonite directly above the anomaly. Drill holes CRB7 (56m) and CRB57
(96m) intersected strong chlorite-sericite-quartz-zeolite alteration, comparable to the propylitic
alteration commonly found distal to porphyry systems. However, these holes did not reach the
Ordovician basement. Post mineral intrusions are common in large, long lived porphyry systems and
as such the occurrence of monzonite dykes is considered encouraging for a large and older intrusive
complex at depth in association with the magnetic anomaly.
Level 14, 333 Collins Street, Melbourne, VIC 3000, Australia. PO Box 143 Kingsway, WA 6065, Australia
ABN 18 606 128 090 T +61 8 6166 0240 F 61 8 6270 5410 E admin@s2resources.com.au W www.s2resources.com.au
In the mid-1990’s, Rio Tinto modelled the magnetic anomaly as being at a depth of 800 metres, and
on this basis concluded that it was too deep to be of interest. However, recent remodelling of the
original source magnetic data using more advanced inversion modelling techniques indicates that the
body sourcing the anomaly is likely to start closer to surface, potentially in the 450-600 metre depth
range.
At this depth, the location of the magnetic body is consistent with it potentially being an intrusion
within the Ordovician Walli Volcanic group (467.3-452.9 million years old – or “Ma”) and overlain by a
thick sequence of Silurian sedimentary and volcanic rocks, including the Canowindra Volcanics of
Llandovery age (440.8-438.5 Ma) and the Avoca Valley Shale (440.8-425.6 Ma).
The interpreted position of the anomaly, within Ordovician volcanics but not in the overlying Silurian
rocks, suggests that the magnetic body was emplaced during the late Ordovician to early Silurian, at
broadly the same time as the Cadia Valley porphyry complex (435.9 – 459.7Ma). Furthermore, the
Silurian (Llandovery) age cover sequence may have been critical in the preservation of any potential
porphyry mineralisation, as it was for the preservation of the Cadia Valley porphyry district.
By way of comparison, the Cadia East deposit, located approximately 55km to the northeast, was
discovered through drill targeting of a magnetic anomaly buried beneath Silurian (Llandovery) age
cover. In this case, 2D inversions of ground magnetic data suggested that a 221 metre hole previously
drilled by Pacific Copper did not properly test the magnetic anomaly at Cadia East. As a result, a vertical
core hole (NC104) drilled to 404 metres in early 1994 intersected magnetite veins, monzonite dykes,
and increasing copper grades at depth, and follow-up drilling discovered the Cadia East deposit
beneath the Silurian (Llandovery) sedimentary cover.
Comparable aeromagnetic responses to the Glenlogan anomaly have also been reported at other
major porphyry copper-gold deposits, including Ridgeway (Australia), Grasberg (Indonesia), Alumbrera
(Argentina), and Buenavista Del Cobre (Mexico), where a central magnetic high is associated with
chalcopyrite-bornite‐magnetite mineralisation in proximal potassic alteration zones, and surrounding
annular magnetic lows are related to magnetite destructive alteration of surrounding rocks.
Project background
The Glenlogan project comprises an exploration licence (EL9614) covering 85 square kilometres in the
highly endowed Lachlan Fold Belt of New South Wales, which contains a number of major gold/copper
deposits, including Newmont’s Cadia-Ridgeway operations (36.6Moz gold/8.3Mt copper), Evolution
Mining’s Cowal (8.8Moz gold) and North Parkes (3.3Moz gold/2.9Mt copper) mines, and Alkane’s
Tomingley (1.8Moz gold) mine and Boda (8.4Moz gold/1.5Mt copper) deposit (see Figure 5).
S2 is earning up to an 80% interest in this project from ASX-listed Legacy Minerals (“Legacy”). The
agreement comprises an earnin and joint venture phase, with key terms as follows:
•
•
•
S2 Legacy with 1 million ordinary shares on signing, representing a consideration of
approximately A$150,000 at a deemed price of A$0.15 per share
Minimum commitment is to drill the Shellback magnetic anomaly within 12 months
and to undertake 1,200 metres of diamond drilling
S2 can spend A$2 million within 2 years of signing to earn a 51% participating interest
Level 14, 333 Collins Street, Melbourne, VIC 3000, Australia. PO Box 143 Kingsway, WA 6065, Australia
ABN 18 606 128 090 T +61 8 6166 0240 F 61 8 6270 5410 E admin@s2resources.com.au W www.s2resources.com.au
•
Following this, S2 can elect to spend a further A$4 million within a further 3 years to
earn an additional 19% interest for a 70% participating interest, including a minimum
of 8,000 metres of diamond drilling
At the earn-in point:
•
•
•
•
•
•
A joint venture will be formed with S2 having up to a 70% participating interest and
Legacy having a 30% participating interest
Legacy will have a one-time choice to retain its participating interest or to convert this
to a 20% carried interest
In the circumstance of a participating interest, Legacy must contribute or dilute
Should Legacy’s participating interest drop below 10%, its interest will revert to a 2%
net smelter return (NSR) royalty
S2 can buy down half of this royalty (ie, 1%) for A$3 million at any time up to 3 years
from a joint venture being formed
In the circumstance of a carried interest, S2 will have an 80% interest and Legacy’s 20%
interest will be funded by S2 up to the commencement of commercial production, with
this being will repayable from 70% of the production revenue attributable to Legacy’s
20% interest in a mining operation
Figure 5. Map showing outcropping areas, known deposits/mines, and the location of the Glenlogan target.
Level 14, 333 Collins Street, Melbourne, VIC 3000, Australia. PO Box 143 Kingsway, WA 6065, Australia
ABN 18 606 128 090 T +61 8 6166 0240 F 61 8 6270 5410 E admin@s2resources.com.au W www.s2resources.com.au
This announcement has been provided to the ASX under the authorisation of the S2 Board.
For further information, please contact:
Mark Bennett
Executive Chairman
+61 8 6166 0240
Past Exploration results reported in this announcement have been previously prepared and disclosed
by S2 Resources Ltd in accordance with JORC 2012. The Company confirms that it is not aware of any
new information or data that materially affects the information included in these market
announcements. The Company confirms that the form and content in which the Competent Person's
findings are presented here have not been materially modified from the original market
announcement. Refer to www.s2resources.com.au for details on past exploration results.
Competent Persons statement
Information in this report that relates to Exploration Results from Victoria is based on information
compiled by Rohan Worland, who is an employee and equity holder of the Company. Mr Worland is a
member of the Australian Institute of Geoscientists (AIG) and has sufficient experience of relevance to
the style of mineralization and the types of deposits under consideration, and to the activities
undertaken, to qualify as a Competent Person as defined in the 2012 Edition of the Joint Ore Reserves
Committee (JORC) Australasian Code for Reporting of Exploration Results, Mineral Resources and Ore
Reserves. Mr Worland consents to the inclusion in this report of the matters based on information in
the form and context in which it appears.
Information in this report that relates to Exploration Results from Western Australia, New South Wales
and Finland is based on information compiled by John Bartlett, who is an employee and equity holder
of the Company. Mr Bartlett is a member of the Australian Institute of Mining and Metallurgy
(MAusIMM) and has sufficient experience of relevance to the style of mineralization and the types of
deposits under consideration, and to the activities undertaken, to qualify as a Competent Person as
defined in the 2012 Edition of the Joint Ore Reserves Committee (JORC) Australasian Code for
Reporting of Exploration Results, Mineral Resources and Ore Reserves. Mr Bartlett consents to the
inclusion in this report of the matters based on information in the form and context in which it appears.
The following Tables are provided to ensure compliance with the JORC code (2012) edition
requirements for the reporting of exploration results.
Level 14, 333 Collins Street, Melbourne, VIC 3000, Australia. PO Box 143 Kingsway, WA 6065, Australia
ABN 18 606 128 090 T +61 8 6166 0240 F 61 8 6270 5410 E admin@s2resources.com.au W www.s2resources.com.au
SECTION 1: SAMPLING TECHNIQUES AND DATA
Criteria
JORC Code explanation
Sampling techniques
Nature and quality of sampling (e.g. cut channels,
random chips, or specific specialised industry
standard measurement tools appropriate to the
minerals under investigation, such as down hole
gamma sondes, or handheld XRF instruments, etc).
These examples should not be taken as limiting the
broad meaning of sampling.
Drilling techniques
Drill sample
recovery
Logging
Sub-sampling
techniques and
sample preparation
Commentary
All results are historical in nature. No sampling by S2 has
been conducted on the tenements
Include reference to measures taken to ensure
sample representivity and the appropriate
calibration of any measurement tools or systems
used
All results are historical in nature. No sampling by S2 has
been conducted on the tenements
Aspects of the determination of mineralisation
that are Material to the Public Report. In cases
where ‘industry standard’ work has been done this
would be relatively simple (e.g. ‘reverse circulation
drilling was used to obtain 1 m samples from
which 3 kg was pulverised to produce a 30 g
charge for fire assay’). In other cases more
explanation may be required, such as where there
is coarse gold that has inherent sampling
problems. Unusual commodities or mineralisation
types (e.g. submarine nodules) may warrant
disclosure of detailed information
All results are historical in nature. No sampling by S2 has
been conducted on the tenements
Drill type (e.g. core, reverse circulation, open-hole
hammer, rotary air blast, auger, Bangka, sonic,
etc) and details (e.g. core diameter, triple or
standard tube, depth of diamond tails, facesampling bit or other type, whether core is
oriented and if so, by what method, etc).
No drilling by S2 has been conducted on the tenements.
Historical drilling (AC, RC & Diamond) has been conducted
across the project area, the verification and validation of
these data sets is ongoing.
Method of recording and assessing core and chip
sample recoveries and results assessed
No drilling or sampling by S2 has been conducted on the
tenements. All drilling on the project is historical in nature
and verification and validation of these data sets are ongoing.
Measures taken to maximise sample recovery and
ensure representative nature of the samples
No drilling or sampling by S2 has been conducted on the
tenements. All drilling on the project is historical in nature
and verification and validation of these data sets are
ongoing.
Whether a relationship exists between sample
recovery and grade and whether sample bias may
have occurred due to preferential loss/gain of
fine/coarse material.
No drilling or sampling by S2 has been conducted on the
tenements. All drilling on the project is historical in nature
and verification and validation of these data sets are ongoing.
Whether core and chip samples have been
geologically and geotechnically logged to a level of
detail to support appropriate Mineral Resource
estimation, mining studies and metallurgical
studies.
No drilling or sampling by S2 has been conducted on the
tenements. All drilling on the project is historical in nature
and verification and validation of these data sets are ongoing.
Whether logging is qualitative or quantitative in
nature. Core (or costean, channel, etc)
photography.
No drilling or sampling by S2 has been conducted on the
tenements. All drilling on the project is historical in nature
and verification and validation of these data sets are ongoing.
The total length and percentage of the relevant
intersections logged
No drilling or sampling by S2 has been conducted on the
tenements. All drilling on the project is historical in nature
and verification and validation of these data sets are ongoing.
If core, whether cut or sawn and whether quarter,
half or all core taken.
No drilling or sampling by S2 has been conducted on the
tenements. All drilling on the project is historical in nature
and verification and validation of these data sets are ongoing.
Level 14, 333 Collins Street, Melbourne, VIC 3000, Australia. PO Box 143 Kingsway, WA 6065, Australia
ABN 18 606 128 090 T +61 8 6166 0240 F 61 8 6270 5410 E admin@s2resources.com.au W www.s2resources.com.au
Criteria
Quality of assay data
and laboratory tests
Verification of
sampling and
assaying
Location of data
points
Data spacing and
distribution
JORC Code explanation
Commentary
If non-core, whether riffled, tube sampled, rotary
split, etc and whether sampled wet or dry.
No drilling or sampling by S2 has been conducted on the
tenements. All drilling on the project is historical in nature
and verification and validation of these data sets are ongoing.
For all sample types, the nature, quality and
appropriateness of the sample preparation
technique.
No drilling or sampling by S2 has been conducted on the
tenements. All drilling on the project is historical in nature
and verification and validation of these data sets are ongoing.
Quality control procedures adopted for all subsampling stages to maximise representivity of
samples.
No drilling or sampling by S2 has been conducted on the
tenements. All drilling on the project is historical in nature
and verification and validation of these data sets are ongoing.
Measures taken to ensure that the sampling is
representative of the in situ material collected,
including for instance results for field
duplicate/second-half sampling.
No drilling or sampling by S2 has been conducted on the
tenements. All drilling on the project is historical in nature
and verification and validation of these data sets are ongoing.
Whether sample sizes are appropriate to the grain
size of the material being sampled.
No drilling or sampling by S2 has been conducted on the
tenements. All drilling on the project is historical in nature
and verification and validation of these data sets are ongoing.
The nature, quality and appropriateness of the
assaying and laboratory procedures used and
whether the technique is considered partial or
total.
No assaying of samples has been conducted by S2 on the
tenements. All sampling on the project is historical in nature
and verification and validation of these data sets are ongoing.
For geophysical tools, spectrometers, handheld
XRF instruments, etc, the parameters used in
determining the analysis including instrument
make and model, reading times, calibrations
factors applied and their derivation, etc.
No assaying of samples has been conducted by S2 on the
tenements. All sampling on the project is historical in nature
and verification and validation of these data sets are ongoing.
Nature of quality control procedures adopted (e.g.
standards, blanks, duplicates, external laboratory
checks) and whether acceptable levels of accuracy
(i.e. lack of bias) and precision have been
established.
No assaying of samples has been conducted by S2 on the
tenements. All sampling on the project is historical in nature
and verification and validation of these data sets are ongoing.
The verification of significant intersections by
either independent or alternative company
personnel.
No assaying of samples has been conducted on the tenements
The use of twinned holes.
No drilling by S2 has been conducted on the tenements.
Documentation of primary data, data entry
procedures, data verification, data storage
(physical and electronic) protocols.
No drilling or sampling has been conducted on the tenements.
All drilling and sampling on the project are historical in nature
and verification and validation of these data sets are ongoing.
Discuss any adjustment to assay data.
No adjustments to the assay data have been carried out by S2.
drilling or sampling has been conducted by S2 on the
tenements.
Accuracy and quality of surveys used to locate
drillholes (collar and down-hole surveys), trenches,
mine workings and other locations used in Mineral
Resource estimation.
No drilling or sampling has been conducted on the
tenements. All drilling and sampling on the project are
historical in nature and verification and validation of these
data sets are ongoing. Only selected historical drill sites have
been verified in the field by S2.
Specification of the grid system used.
The grid system used by S2 is GDA94 (MGA), zone 55.
Historical results have been reported in various grid formats
and these have been converted to a standard grid system in
QGIS.
Quality and adequacy of topographic control.
Elevation data for all data is determined by a digital elevation
model derived from public domain SRTM 10m Elevation grids
Data spacing for reporting of Exploration Results.
No drilling or sampling has been conducted by S2 on the
tenements. Historical drilling and sampling have been carried
out on various grid spacings as well as isolated, ad hoc
manner.
Level 14, 333 Collins Street, Melbourne, VIC 3000, Australia. PO Box 143 Kingsway, WA 6065, Australia
ABN 18 606 128 090 T +61 8 6166 0240 F 61 8 6270 5410 E admin@s2resources.com.au W www.s2resources.com.au
Criteria
JORC Code explanation
Commentary
Whether the data spacing and distribution is
sufficient to establish the degree of geological and
grade continuity appropriate for the Mineral
Resource and Ore Reserve estimation procedure(s)
and classifications applied.
No assaying of samples has been conducted by S2 on the
tenements. All drilling and sampling on the project are
historical in nature and verification and validation of these
data sets are ongoing.
Whether sample compositing has been applied.
No sample compositing has been applied by S2
Whether the orientation of sampling achieves
unbiased sampling of possible structures and the
extent to which this is known, considering the
deposit type.
All drilling and sampling on the project are historical in nature
and verification and validation of these data sets are ongoing.
If the relationship between the drilling orientation
and the orientation of key mineralised structures is
considered to have introduced a sampling bias,
this should be assessed and reported if material.
All drilling and sampling on the project are historical in nature
and verification and validation of these data sets are ongoing.
Sample security
The measures taken to ensure sample security.
All drilling and sampling on the project is historical in nature
and S2 is currently unable to verify what (if any measures)
have been taken.
Audits or reviews
The results of any audits or reviews of sampling
techniques and data.
No audits or reviews have been conducted by S2 at this stage.
Orientation of data
in relation to
geological structure
SECTION 2: REPORTING OF EXPLORATION RESULTS
Criteria
JORC Code explanation
Mineral tenement
and land tenure
status
Commentary
The Glenlogan project comprises one exploration licences (see list
below), covering approximately 85 square kilometres.
Type, reference name/number, location and
ownership including agreements or material
issues with third parties such as joint ventures,
partnerships, overriding royalties, native title
interests, historical sites, wilderness or national
park and environmental settings.
The tenements is held in the name of Legacy Minerals Pty Ltd and
is subject to Earn-in Joint Venture with S2 Resources Ltd (terms
outlined in text of this announcement).
TENID
TENSTATUS
HOLDER
EL 9614
LIVE
Legacy Minerals Pty Ltd
The project is located east of the township of Cowra, within the
Central West region of New South Wales. Access to the project is
via the Mid Western Highway, Olympic Highway and Lachlan
Valley Way, which pass through the tenement.
The security of the tenure held at the time of
reporting along with any known impediments to
obtaining a licence to operate in the area.
EL9614 is a granted exploration licence within in New South Wales
and the current term of grant is until 11 February 2026, with the
licence currently considered in good standing.
Prior to accessing the ground S2 is required to obtain signed land
access agreements with the landowners.
Level 14, 333 Collins Street, Melbourne, VIC 3000, Australia. PO Box 143 Kingsway, WA 6065, Australia
ABN 18 606 128 090 T +61 8 6166 0240 F 61 8 6270 5410 E admin@s2resources.com.au W www.s2resources.com.au
Criteria
JORC Code explanation
Exploration done
by other parties
Commentary
Historical exploration within the project area has been limited. In
1982, Mines Exploration completed a single deep drill hole,
DDHCV1, to a depth of 629m. The hole, located 1km to the west
of the magnetic target, intersected Devonian sediments to end of
hole at 629m supporting the interpretation of a major fault to the
west of the magnetic target.
Acknowledgment and appraisal of exploration
by other parties.
Reconnaissance drilling in 1992 was completed by Placer
Exploration Limited and intercepted altered monzonite at end of
hole shallow percussion holes drilled directly above the Cowra
Target. Drill holes CRB7 (56m) and CRB57 (96m) were strongly
altered by chlorite-sericite-quartz-zeolite, comparable to the
propylitic alteration commonly found distal to porphyry systems.
Drill holes did not reach the Ordovician basement which is
interpreted to be at approximately 450m depth. Post mineral
intrusions are common in large, long lived mineral systems and as
such the observation of monazite in drilling is considered
encouraging for a large and older intrusive complex at depth in
association with the magnetic anomaly.
Rio Tino held the project between 1994-1997, undertaking
Magnetic modelling which suggested the magnetic anomaly was
approximately 800m below surface, thus the likelihood of a largescale mineral system associated with the magnetic source was not
likely to be amenable to shallow mining methods and drilling was
therefore not conducted.
Geology
The Glenlogan Project is in the Central Lachlan Fold Belt, NSW,
which hosts world-class Au-Cu orebodies including the CadiaRidgeway, Northparkes and Cowal Mines. The project is
considered prospectve for copper-gold porphyry intrusions
and/or associated skarn style copper-gold.
The exploration tenement covers the western margin of the
Siluro-Devonian Cowra trough, located in the Forbes Anticlinal
Zone of the Lachlan Fold Belt. The Ordovician Macquarie Arc
volcanics are interpreted to be buried beneath these later
geological units.
Deposit type, geological setting and style of
mineralisation.
The “Shellback” magnetic anomaly is modelled to intrude to
within 450 – 600m of surface, suggesting the body has not
intruded into the overlying Silurian sequence, thus suggesting
the magnetic body was emplaced during the early Silurian to late
Ordovician, which is a similar timing to the Cadia Valley porphyry
complex (435.9 – 459.7Ma). It is considered that the Silurian age
cover sequence will have been critical in the preservation of any
potential porphyry mineralisation across the Glenlogan Project,
as it was for the preservation of the Cadia Valley porphyry
district.
Comparable aeromagnetic responses to those present at the
Glenlogan project have been reported at other major porphyry
Cu-Au deposits, including: Cadia East (AUS), Grasberg (IND),
Alumbrera (ARG), and Buenavista Del Cobre (MEX). The strong
magnetic response suggests a discrete central magnetic high
possibly due to chalcopyrite-bornite‐magnetite mineralisation,
associated with a porphyry proximal potassic alteration zone,
surrounded by an annular magnetic low due to magnetite
destructive hydrothermal alteration of surrounding rock,
features that are characteristic of globally important Cu-Au
porphyry deposits.
Level 14, 333 Collins Street, Melbourne, VIC 3000, Australia. PO Box 143 Kingsway, WA 6065, Australia
ABN 18 606 12
Share your feedback
Discover