Three Untested Copper-Gold Targets Defined at Rockley
Released
Released
Announcement PDF
Page 1 of 18 | ABN 43 650 398 897
12/217 Howick St, Bathurst, 2795
www.legacyminerals.com.au
See Endnotes on Page 16 for references
Refer to Disclaimer on Page 9
Three Untested Copper-Gold Targets Defined at Rockley, NSW
Three untested IP chargeability targets defined at Crystal Hill up to 45mV/V, including a
priority 800m-long target coincident with surface copper-gold-silver anomalism
THREE NEW CHARGEABILITY TARGETS DEFINED
• An induced polarisation (IP) survey completed recently over the Crystal Hill Prospect at Legacy’s
100%-owned Rockley Project, 25km west of Oberon, NSW, has defined three discrete chargeability
targets exceeding 35mV/V, none of which have been drill tested.
• The Central target is the highest priority target identified by the survey, comprising a north-north-
west trending zone with responses up to 45mV/V over an 800m strike length, modelled from a 100m
depth and coincident with the Crystal Hill soil geochemistry anomaly.
STRONG RESPONSES MODELLED FROM SHALLOW DEPTH
• The North-West target is a strong zone of more than 40mV/V modelled from approximately 200m
depth and the East target is a 35mV/V zone at approximately 200m depth within a resistive zone.
• Chargeability responses of this nature can reflect disseminated sulphide mineralisation or alteration.
COINCIDENT WITH HIGH-GRADE SURFACE COPPER, GOLD AND SILVER
• The Central target sits beneath the Crystal Hill soil anomaly, where nearby rock chip samples
returned assays of up to 9.3% Cu, 3.9g/t Au, and 415g/t Agi
.
• None of the three priority IP targets has been tested by historical drilling.
• Integration of the inversion models with geology, mapping and geochemistry is underway, with drill
testing of the three targets under consideration.
HIGHLY PROSPECTIVE ORDOVICIAN MACQUARIE ARC SETTING
• Rockley (EL8926) was assessed by Kenex Pty Ltd, in conjunction with the Geological Survey of NSW,
as one of the most prospective areas for porphyry-related copper-gold mineralisation in the Rockley-
Gulgong Volcanics.
• The Project sits within the Ordovician Macquarie Arc, which also hosts the Cadia Valley, North Parkes
and Cowal copper-gold deposits, and is located less than 15km from the Bushranger Deposit, where
drilling has intersected 920m at 0.3% Cu from 110m, including 156m at 0.48% Cuxiii.
Figure 1. Rock chip samples 5966 and 9738 from the Crystal Hill Prospect, Rockley, with assay results inset1
.
ASX Announcement
22 September 2026 ASX: LGM
ASX: LGM
SIGN UP TO LEGACY MINERALS’
INTERACTIVE INVESTOR HUB
Page 2 of 18
Legacy Minerals Holdings Limited (ASX: LGM, “Legacy Minerals” or “the Company”) is pleased to report the
results from a recently completed IP survey at the Crystal Hill Prospect, within its 100%-owned Rockley
Project (the Project) (EL8926) in the Lachlan Fold Belt, NSW, approximately 25km west of Oberon.
Management Comment Legacy Minerals CEO and Managing Director, Christopher Byrne, said:
“It’s hard to ask for better drill targets than these three clear, untested copper targets at Rockley. The
most compelling target sits directly beneath the copper, gold and silver anomaly we mapped during
previous campaigns.
Our strategy at Rockley has always been to determine whether the high-grade copper and gold we see
at the surface reflects a larger system at depth. This is the first time we have an extremely high-conviction
geophysical response, up 45mV/V over an 800m strike length, coincident with highly anomalous surface
geochemistry. This is ground that has never been drilled, and it lies in the same-aged volcanics that host
the world-class Cadia-Ridgeway deposits.
Our focus now is to integrate this modelling with our geology and geochemistry and to work towards
drill testing these targets. Like our recent work at NiCo Young, the Company plans to advance these
generative projects alongside the ongoing programs at Mt Carrington, providing shareholders with
additional critical mineral and copper discovery exposure.”
Figure 2. Perspective view from the south-east showing the 2D inverted chargeability sections and the 3D
inverted chargeability iso-shells (30, 40, 50 and 60mV/V). Coloured points are soil geochemistry, coloured
and sized by antimony (Sb). The North-West, Central and East targets are shown from left to right.ii
ASX: LGM
SIGN UP TO LEGACY MINERALS’
INTERACTIVE INVESTOR HUB
Page 3 of 18
Chargeability Targets
Two-dimensional (2D) and three-dimensional (3D) inversion modelling of the survey data has defined
three discrete zones of elevated chargeability (Table 1). The most significant of these is a north-north-
west trending zone of approximately 800m strike extent that is coincident with the Crystal Hill soil
geochemistry anomaly. None of the three zones has been drill tested.
Figure 3. The Crystal Hill magnetic low target area (white dashed line) with 3D inverted chargeability iso-
shells over highlight rock chip assays, historic workings, and geologyi
.
ASX: LGM
SIGN UP TO LEGACY MINERALS’
INTERACTIVE INVESTOR HUB
Page 4 of 18
Figure 4. The Crystal Hill magnetic low target area (white dashed line) with 3D inverted chargeability iso-
shells (>35mV/V) over highlight rock chip assays, historic workings and geology, as previously reported in
the ASX release of 14 October 2024.
ASX: LGM
SIGN UP TO LEGACY MINERALS’
INTERACTIVE INVESTOR HUB
Page 5 of 18
The three chargeability targets defined by the 2D and 3D inversion modelling are shown in Figure 3
and summarised in Table 1. They are described below.
Table 1. Summary of the modelled chargeability targets defined by the 2026 Rockley IP survey. Positions are
given in the local survey grid. Depths are modelled depths below surface and are not true widths of
mineralisation.
Target Survey line(s) Local grid
position
Modelled
depth
Peak
modelled
chargeability
Comment
North-
West
21950N 10800E ~200m >40mV/V Discrete zone at the western end of
the northernmost line.
Central 20600N,
21050N,
21500N
11200E to
11800E
~100m to
200m
45mV/V+ NNW trending, ~800m strike extent,
coincident with the soil
geochemistry anomaly. Highest
priority target.
East 21050N 12200E ~200m 35mV/V Hosted within a resistive zone,
unlike the other two targets.
Chargeability in millivolts per volt (mV/V) measures the ability of the ground to hold an electrical
charge and can be elevated in response to disseminated sulphide minerals, alteration, graphite, clay
or other lithological variation.
North-West target: a strong chargeability anomaly of more than 40mV/V centred at approximately
200m depth at 10800E on Line 21950N, where the resistivity model also shows a change from resistive
in the west to conductive in the east that is interpreted to reflect the schist and metabasalt contact
mapped in the regional geology.
Central target: a north-north-west trending linear zone of approximately 800m strike extent defined
across Lines 21500N, 21050N and 20600N, with modelled chargeability of up to 45mV/V from
approximately 100m depth. The zone is coincident with the Crystal Hill soil geochemistry anomaly and
is considered the most prospective target defined by the survey.
East target: a 35mV/V chargeable zone at 12200E on Line 21050N at approximately 200m depth. This
target is distinguished from the other two by sitting within a resistive rather than a conductive zone.
Key features identified at the Rockley Project include:
1. The presence of copper oxides (malachite and azurite) and copper sulphides (chalcopyrite) in
rock chips from outcrop and as float near historic workings over an area at least 3km2
.
2. Assays up to 9.3% copper, 3.9g/t gold and 415g/t silver with associated anomalous molyb-
denum (up to 28.5ppm), lithium (40ppm), beryllium (2.1ppm), tellurium (19ppm), arsenic
(1,845ppm) and antimony (5,550ppm). iii
3. Higher grade copper assays occur in focussed zones associated with 3rd
order faults of the
parent Native Dog Fault. These fault zones may have potentially tapped a mineralised intru-
sion at depth (Figure 8).
4. The coincidence of an area of extensive copper oxide bearing rocks with several potassium
highs, evident in the radiometric data coincident within the regionally aeromagnetic high
Rockley-Gulgong volcanic unit, may be suggestive of porphyry-proximal magnetite bearing
potassic alteration zones at depth.
ASX: LGM
SIGN UP TO LEGACY MINERALS’
INTERACTIVE INVESTOR HUB
Page 6 of 18
iv
Figure 5. Location of the Rockley Project, the Lachlan Transverse Zone, and the Macquarie Arc.v
Implications of the IP Response for Potential Sulphide Mineralisation
Chargeability measures how strongly the ground stores an electrical charge, and in porphyry and vein
systems it is most commonly generated by disseminated sulphide minerals such as pyrite, pyrrhotite
and chalcopyrite. The three targets, at 35mV/V to more than 45mV/V, are an order of magnitude
above the 3mV/V background.
The resistivity models add a second dimension to the interpretation. The Central target sits within a
conductive zone, the response expected where sulphides occur with potentially sericite altered wall
rock. The East target is the opposite, a chargeable zone within resistive ground, a pairing more typically
associated with sulphides hosted in silicified or quartz veined rock. The North-West target sits near a
modelled resistivity contact interpreted to reflect the schist and metabasalt contact, a lithological
contrast that may have localised mineralisation.
Sulphide minerals are already documented at surface across the target area. Mapping and rock chip
sampling at Crystal Hill identified quartz-pyrite veins with variable copper oxides (malachite and
azurite) and copper sulphide (chalcopyrite), and gossanous and sulphide veins carrying pyrite and
pyrrhotite (refer ASX release 14 October 2024). The modelled chargeability zones sit beneath and
adjacent to that mineralisation and beneath the coincident gold, arsenic, molybdenum and antimony
soil anomaly, at modelled depths of approximately 50m to 200m.
Chargeability is not diagnostic of mineralisation. Clay alteration, disseminated magnetite and
serpentinised ultramafic rocks can all produce elevated chargeability, and several of those are
plausible within the Ordovician mafic-ultramafic and sedimentary sequence mapped at Rockley.
The Central target is the Company’s priority for drill testing as it combines the largest modelled strike
extent, chargeability of up to 45mV/V and direct coincidence with the surface geochemical anomaly
and its position adjacent to the mapped workings at Crystal Hill.
ASX: LGM
SIGN UP TO LEGACY MINERALS’
INTERACTIVE INVESTOR HUB
Page 7 of 18
Surface Geochemistry at Crystal Hill
Figure 6. The Crystal Hill magnetic low target area (white dash line) with soil assay results (Sb and Mo),
highlight rock chip assays, and geology.
Figure 7. The Crystal Hill magnetic low target area (white dash line) with soil assay results (Au and As),
highlight rock chip assays, and geology.
ASX: LGM
SIGN UP TO LEGACY MINERALS’
INTERACTIVE INVESTOR HUB
Page 8 of 18
The Central target is coincident with the Crystal Hill soil geochemical anomaly (Figures 6 and 7), which
was defined by a first pass soil survey of 570 samples completed on a 200m by 100m grid across 12km2
of the Project. Those results delineated an extensive central zone of elevated gold, arsenic,
molybdenum and antimony with less coherent but elevated copper, lead and zinc, with peak values
of 1,170ppb Au, 2.12ppm Ag, 1,035ppm Cu, 815ppm As, 9.58ppm Mo and 194ppm Sb (refer ASX
release 14 October 2024).
Reconnaissance rock chip sampling over the same area (Figure 1) returned assays of up to 9.3% Cu,
3.9g/t Au, 415g/t Ag, 28.5ppm Mo, 5,550ppm Sb and 1,845ppm As from quartz veined and brecciated
Ordovician mafic and ultramafic rocks associated with historic workings and vein trends. The
anomalous area is approximately 3km2 in size. The potential of the Crystal Hill Prospect remains
untested, with no systematic exploration and only a small number of shallow reconnaissance drill
holes (less than 14m depth) completed more than 25 years ago.
Geochemical Exploration for Porphyry Copper Gold Deposits
Fundamental to the exploration process of porphyry copper-gold deposits is to understand the nature
and distribution of pathfinder elements, metal zonation, and alteration mineral assemblage. These
zones form around deposits providing indications to the level of the porphyry system and vectors to
the higher-grade mineralised core (Figure 8).
Figure 8. Diagram showing the pathfinder geochemical and alteration patterns of a typical porphyry copper-
gold mineral system and the relative location of Rockley.
Next Steps
The Company is integrating the 2D and 3D inversion models with its geological mapping, structural
interpretation, soil and rock chip geochemistry to refine and prioritise the three targets for drill
testing. Drill testing of the three chargeability anomalies is under consideration and remains subject
to drill planning, landholder access, statutory approvals and funding. The Company will update the
market as this work progresses.
ASX: LGM
SIGN UP TO LEGACY MINERALS’
INTERACTIVE INVESTOR HUB
Page 9 of 18
Approved by the Board of Legacy Minerals Holdings Limited
For more information:
Investors:
Chris Byrne
CEO & Managing Director
chris.byrne@legacyminerals.com.au
+61 (0) 499 527 547
Media:
Nicholas Read
Read Corporate
nicholas@readcorporate.com.au
+61 (0) 419 929 046
DISCLAIMER AND PREVIOUSLY REPORTED INFORMATION
Information in this announcement is extracted from reports lodged as market announcements referred to
above and available on the Company’s website https://legacyminerals.com.au/ and on the Company’s
Investor Hub. In particular, the soil geochemical and rock chip results referred to in this announcement are
extracted from the ASX release “New Copper-Gold Prospects Defined at Crystal Hill, Rockley” dated 14
October 2024, and the earlier Rockley geophysical and rock chip results are extracted from the ASX releases
dated 27 July 2022 and 4 April 2022. The Company confirms that it is not aware of any new information
that materially affects the information included in those original market announcements and that all
material assumptions and technical parameters underpinning the results in those announcements
continue to apply and have not materially changed.
This announcement contains certain forward-looking statements, including statements regarding the
interpretation of the induced polarisation survey results and the nature, scope and timing of further
exploration at the Rockley Project. Forward-looking statements are only predictions and are subject to
risks, uncertainties and assumptions which are outside of the control of Legacy Minerals Holdings Limited
(LGM). These risks, uncertainties and assumptions include commodity prices, currency fluctuations,
economic and financial market conditions, environmental risks and legislative, fiscal or regulatory
developments, political risks, project delay, approvals and cost estimates. The chargeability anomalies
reported in this announcement are geophysical responses that have not been drill tested, and there is no
certainty that they reflect mineralisation or that any mineralisation will be discovered. Actual values,
results or events may be materially different to those contained in this announcement. Given these
uncertainties, readers are cautioned not to place reliance on forward-looking statements. Any forward-
looking statements in this announcement reflect the views of LGM only at the date of this announcement.
Subject to any continuing obligations under applicable laws and ASX Listing Rules, LGM does not undertake
any obligation to update or revise any information or any of the forward-looking statements in this
announcement to reflect changes in events, conditions or circumstances on which any forward-looking
statement is based.
COMPETENT PERSON’S STATEMENT
The information in this announcement that relates to Exploration Targets, Exploration Results, Mineral
Resources or Ore Reserves across the broader Legacy Minerals portfolio is based on information compiled
by Thomas Wall, a Competent Person who is a Member of the Australian Institute of Geoscientists. Mr Wall
is the Technical Director and a full-time employee of Legacy Minerals Pty Limited, the Company’s wholly-
owned subsidiary, and a shareholder of the Company. Mr Wall has sufficient experience that is relevant to
the style of mineralisation and type of deposit under consideration and to the activity being undertaken to
qualify as a Competent Person as defined in the 2012 edition of the Australasian Code for Reporting of
Exploration Results, Mineral Resources and Ore Reserves. Mr Wall consents to the inclusion of the matters
based on this information in the form and context in which it appears in this announcement.
ASX: LGM
SIGN UP TO LEGACY MINERALS’
INTERACTIVE INVESTOR HUB
Page 10 of 18
About Legacy Minerals
Legacy Minerals is an ASX-listed public company that has been exploring gold, silver, copper, nickel and base-
metal projects in NSW since 2017. The Company’s projects present significant discovery opportunities for
shareholders, with a focus on discovery drilling and the development of the Mt Carrington Project.
Cu-Au Mt Carrington (EL6273, EL9616, EL9727, ALA75)
Large caldera (~150km2
) with similar geological characteristics to other major Pacific Rim low-sulphidation deposits. The
current Mineral Resource of 1.6Moz AuEq (refer ASX release 30 July 2026).
Au-Ag Bauloora
One of NSW’s largest low-sulphidation, epithermal
systems with a 15 km2
epithermal vein field.
Ni-Co-Sc NiCo Young Cobalt Blue MoU
One of Australia’s largest nickel and cobalt deposits, with
a combined Ni-Co-Sc Mineral Resource update underway.
Cu-Au Rockley
Prospective for porphyry Cu-Au, situated in the Macquarie
Arc Ordovician host rocks with historical high-grade
copper mines.
Au-Cu (Pb-Zn) Cobar Aurelia Metals Earn-In
Undrilled targets next door to the Peak Gold Mines and
along strike of the CSA copper mine.
Au-Ag Black Range
Extensive low-sulphidation, epithermal system with
limited historical exploration. Epithermal occurrences
across 30 km of strike.
Au Harden Hill Tops Joint Venture
Substantial historical gold production from two high-grade
and underexplored, orogenic systems.
Cu-Au Thomson
A new and unexplored Intrusion-related gold and copper
search space with numerous ‘bullseye’ targets.
Au-Cu Fontenoy Earth AI Joint Venture
A highly prospective and underexplored area for PGE, Ni,
Au and Cu mineralisation with significant drill intercepts.
Figure 9.Location summary of Legacy Minerals’ Projects in NSW, Australia, and major mines and deposits
ASX: LGM
SIGN UP TO LEGACY MINERALS’
INTERACTIVE INVESTOR HUB
Page 11 of 18
Appendix 1 – JORC Code, 2012 Edition Table 1
Section 1 Sampling Techniques and Data
Criteria JORC Code Explanation Commentary
Sampling
Techniques
Nature and quality of sampling (e.g., cut channels,
random chips, or specific specialised industry
standard measurement tools appropriate to the
minerals under investigation, such as down hole
gamma sondes, or handheld XRF instruments, etc).
These examples should not be taken as limiting the
broad meaning of sampling.
No physical sampling was undertaken for the
results reported in this announcement. The
results are from a ground IP survey
completed using a PDIP array over five lines,
with receiver arrays totalling 7,800m.
Sampling
Techniques
Include reference to measures taken to ensure
sample representivity and the appropriate
calibration of any measurement tools or systems
used.
Receiving electrodes were standard non-
polarising porous pots and transmitter
electrodes were buried metal plates. The
transmit frequency was 0.125Hz (2 seconds
on-time, 2 seconds off-time). Final
chargeability was calculated using the
standard integration window for 0.125Hz
data of 590ms to 1,540ms. Readings were
taken synchronously on both sides of the
transmitter dipole on all sixteen receiver
dipoles for every transmitter position.
Sampling
Techniques
Aspects of the determination of mineralisation
that are Material to the Public Report.
In cases where ‘industry standard’ work has
been done this would be relatively simple (e.g.
‘reverse circulation drilling was used to obtain 1 m
samples from which 3 kg was pulverised to produce
a 30 g charge for fire assay’). In other cases more
explanation may be required, such as where there is
coarse gold that has inherent sampling problems.
Unusual commodities or mineralisation types (e.g.,
submarine nodules) may warrant disclosure of
detailed information.
No mineralisation is reported. Modelled
chargeability and resistivity anomalies are
geophysical responses that may reflect
sulphide mineralisation, alteration or other
lithological variation and require drill testing
to determine their source.
Drilling
techniques
Drill type (e.g., core, reverse circulation, open‐hole
hammer, rotary air blast, auger, Bangka, sonic, etc)
and details (e.g., core diametre, triple or standard
tube, depth of diamond tails, facesampling bit or
other type, whether core is oriented and if so, by
what method, etc).
Not applicable. No drilling has been
completed.
Drill sample
recovery
Method of recording and assessing core and
chip sample recoveries and results assessed.
Not applicable. No drilling has been
completed.
Drill sample
recovery
Measures taken to maximise sample recovery and
ensure representative nature of the samples.
Not applicable. No drilling has been
completed.
Drill sample
recovery
Whether a relationship exists between sample
recovery and grade and whether sample bias may
have occurred due to preferential loss/gain of
fine/coarse material.
Not applicable. No drilling has been
completed.
Logging Whether core and chip samples have been
geologically and geotechnically logged to a level of
detail to support appropriate Mineral
Resource estimation, mining studies and
metallurgical studies.
Not applicable. No drilling or physical
sampling is reported. IP data were quality
controlled in TQIPdb, with individual
chargeability decays inspected at each
station.
Logging Whether logging is qualitative or quantitative in
nature. Core (or costean, channel, etc) photography.
Geophysical data are quantitative. Decays
that were noisy, returned poor repeats or
had very low primary received voltage were
ASX: LGM
SIGN UP TO LEGACY MINERALS’
INTERACTIVE INVESTOR HUB
Page 12 of 18
flagged in the database and excluded from all
subsequent processing and inversion.
Logging The total length and percentage of the relevant
intersections logged.
Not applicable. No drilling has been
completed.
Sub‐sampling
techniques and
sample
preparation
If core, whether cut or sawn and whether quarter,
half or all core taken.
Not applicable. No drilling has been
completed.
Sub‐sampling
techniques and
sample
preparation
If non‐core, whether riffled, tube sampled,
rotary split, etc and whether sampled wet or
dry.
Not applicable. No drilling has been
completed.
Sub‐sampling
techniques and
sample
preparation
For all sample types, the nature, quality and
appropriateness of the sample preparation
technique.
Not applicable. No physical sampling or
assaying is reported in this announcement.
Sub‐sampling
techniques and
sample
preparation
Quality control procedures adopted for all
subsampling stages to maximise representivity of
samples.
Not applicable. No physical sampling or
assaying is reported in this announcement.
Sub‐sampling
techniques and
sample
preparation
Measures taken to ensure that the sampling is
representative of the in-situ material collected,
including for instance results for field
duplicate/second‐half sampling.
Not applicable. No physical sampling or
assaying is reported in this announcement.
Sub‐sampling
techniques and
sample
preparation
Whether sample sizes are appropriate to the
grain size of the material being sampled.
Not applicable. No physical sampling or
assaying is reported in this announcement.
Quality of
assay data and
laboratory
tests
The nature, quality and appropriateness of the
assaying and laboratory procedures used and
whether the technique is considered partial or total.
Not applicable. No assays are reported.
Inversion modelling was completed by Mitre
using Res2DInv and Res3DInv from Aarhus
Geosoftware.
Quality of
assay data and
laboratory
tests
For geophysical tools, spectrometres, handheld XRF
instruments, etc, the parametres used in
determining the analysis including instrument make
and model, reading times, calibrations
factors applied and their derivation, etc.
The survey was acquired by Fender
Geophysics between 26 August and 4
September 2026 using a GDD TxIV 5kVA
transmitter and a GDD GRx8-32 16 channel
receiver at a transmit frequency of 0.125Hz.
Line 20020N was surveyed using a Fender
Thunderbird 18kVA transmitter following a
fault in the primary transmitter. Equipment
was operated in accordance with the
manufacturer’s and the contractor’s
standard procedures. The 3D inversion used
a mesh of 25m along line by 75m between
lines, with a 25m thick surface cell and cell
thickness increasing by a factor of 1.1 with
depth, transformed to GDA94 / MGA Zone 55
on a regular 25m mesh.
Quality of
assay data and
laboratory
tests
Nature of quality control procedures adopted
(e.g., standards, blanks, duplicates, external
laboratory checks) and whether acceptable
levels of accuracy (i.e., lack of bias) and precision
have been established.
Data quality was generally good with clean
and repeatable decays. On Line 20600N, four
stations returned strongly negative
chargeability decays adjacent to high positive
values. Testing included swapping wires and
connectors, re-seating, swapping and re-
watering pots and using single core cables,
and repeat readings the following day
reproduced the response closely. In the
absence of any infrastructure in the area the
ASX: LGM
SIGN UP TO LEGACY MINERALS’
INTERACTIVE INVESTOR HUB
Page 13 of 18
response was concluded to be geological
rather than instrumental. Readings flagged
as low quality were not used at any
subsequent stage of processing.
Verification of
sampling and
assaying
The verification of significant intersections by
either independent or alternative company
personnel.
No intersections are reported. The inversion
models and the interpreted targets were
reviewed by the Company’s technical staff
and by Mitre.
Verification of
sampling and
assaying
The use of twinned holes. Not applicable. No drilling has been
completed.
Verification of
sampling and
assaying
Documentation of primary data, data entry
procedures, data verification, data storage
(physical and electronic) protocols.
Raw IP data supplied by Fender Geophysics
were imported into TQIPdb for quality
control and processing. Validated data,
processed data, 2D and 3D inversion models,
section plots, depth slice images and 3D iso-
shells were supplied to the Company as
digital deliverables and are stored on the
Company’s servers.
Verification of
sampling and
assaying
Discuss any adjustment to assay data. No adjustments have been made other than
the standard quality control, filtering and
inversion modelling described above.
Location of
data points
Accuracy and quality of surveys used to locate drill
holes (collar and down‐hole surveys), trenches, mine
workings and other locations used in Mineral
Resource estimation.
The survey was completed on a local grid.
The local grid origin (10000E, 20000N)
corresponds to 740067.6mE, 6265566.2mN
(GDA94 / MGA Zone 55), with a line bearing
of 065 degrees (Line 21500N at 067 degrees).
Electrode positions were surveyed by the
geophysical contractor.
Location of
data points
Specification of the grid system used. Local survey grid, transformed to GDA94 /
MGA Zone 55.
Location of
data points
Quality and adequacy of topographic control. Electrode elevations were extracted from
topographic data downloaded from the NSW
Elevation Data Service and integrated into
the IP database and the inversion models.
Data spacing
and
distribution
Data spacing for reporting of Exploration
Results.
Five PDIP lines spaced nominally 450m apart,
with 100m receiver dipoles and the
transmitter pole advanced 100m per reading.
Data spacing
and
distribution
Whether the data spacing and distribution is
sufficient to establish the degree of geological and
grade continuity appropriate for the Mineral
Resource and Ore Reserve estimation procedure(s)
and classifications applied. Whether sample
compositing has been applied.
Not applicable. No Mineral Resource or Ore
Reserve is reported. The line and dipole
spacing is appropriate to first pass target
definition at this stage of exploration.
Data spacing
and
distribution
Whether sample compositing has been applied. Not applicable. No compositing has been
applied.
Orientation of
data in relation
to geological
structure
Whether the orientation of sampling achieves
unbiased sampling of possible structures and
the extent to which this is known, considering
the deposit type.
Survey lines were oriented at 065 degrees,
approximately perpendicular to the north-
north-west trend of the mapped structures
and soil geochemical anomalism at Crystal
Hill. Line location and length were restricted
by the property boundary, and Line 21500N
was rotated to 067 degrees to maximise
coverage within that boundary.
ASX: LGM
SIGN UP TO LEGACY MINERALS’
INTERACTIVE INVESTOR HUB
Page 14 of 18
Orientation of
data in relation
to geological
structure
If the relationship between the drilling
orientation and the orientation of key
mineralised structures is considered to have
introduced a sampling bias, this should be
assessed and reported if material.
Not applicable. No drilling has been
completed. Modelled chargeability zones are
reported as modelled positions and depths
below surface and no true widths are
implied.
Sample
security
The measures taken to ensure sample security. Not applicable. No physical samples were
collected. Digital data were transferred
directly between the geo
Share your feedback